Subpart E compliance for ACBM inspections

Machine-extracted title · confidence 54%

Policy language on clean areas, HEPA filtration, and sampling expectations for asbestos work.

NYC-WTC_000389978–000390013
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Environmental Protection Agency Pt. 763, Subpt. E, App. A

TABLE 1—NUMBER OF 200 MESH EM GRID OPENINGS (0.0057 MM^) THAT NEED TO BE ANALYZED TO MAINTAIN SENSITIVITY OF 0.005 STRUCTURES/CC BASED ON VOLUME AND EFFECTIVE FILTER AREA

Effective Finer Area Efiecltve Finer Area 385 sq mm __ 855 sq mm Volume (liters) 4 of arid openirxis 560 24 1.250 24 600 23 1,300 23 700 19 1,400 21 BOO 17 1,600 19 900 15 1,800 17 1,000 14 2,000 15 1,100 12 2,200 I 1,200 1 1 2,400 13 I 1,300 10 2,600 12 Recommended 1,400 10 2,800 1 1 I Volume 1,500 9 3,000 10 I Range 1,600 8 3,200 9 Recommended I 1,700 8 3,400 9 Volume I 1,800 8 3,600 8 Range 1,900 7 3,800 8 I 2,000 7 4,000 8 I 2,100 6 4,200 7 2,200 6 4,400 7 2,300 6 4,600 7 2,400 6 4,800 6 2,500 5 5,000 6 2,600 5 5,200 6 2.700 5 5,400 6 2,800 5 5,600 5 2,900 5 5,800 5 3,060 5 6,000 5 3,100 6,200 5 3,200 4 6,400 5 3,300 4 6,600 5 3,400 4 6,800 3,500 4 7,000 4 3,600 4 7,200 4 3,700 4 7,400 3.800 4 7.600 4

Note mininum volumes required: 25 mm : 560 Hers 37 mm ; 1250 Mers

Finer diameter ol 25 mm - eflsctive area st 385 sq mm Finer diameter ot 37 mm - eflsctive area of 855 sq mm

20. Ensure that the sampler is turned up­ 22. Ensure that the samples are stored in a right before interrupting the pump flow. secure and representative location. 21. Check that all samples are clearly la­ 23. Do not change containers if portions of beled and that all pertinent Information has these filters are taken for other purposes. been enclosed before transfer of the samples 24. A summary of Sample Data Quality Ob­ to the laboratory. jectives is shown in the following Table II;

673

NYC-WTC_000389982

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000389982Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →