NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 36 pages

Subpart E compliance for ACBM inspections

Machine-extracted title · confidence 54%

Policy language on clean areas, HEPA filtration, and sampling expectations for asbestos work.

NYC-WTC_000389978–000390013
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pt. 763, Subpt. E, App. A 40 CFR Ch. I (7-1-00 Edition) in diameter at crossover. The microscope 1. Standard replica grating may be used to shall be calibrated routinely (see Unit III.J.) determine magnification (e.g., 2160 lines/ for magnification and camera constant. mm), b. While not required on every microscope ii. Gold standard may be used to determine in the laboratory, the laboratory must have camera constant. either one microscope equipped with energy c. Use a specimen holder with single tilt dispersive X-ray analysis or access to an and/or double tilt capabilities. equivalent system on a TEM in another lab­ 2. Procedure. oratory, This must be an Energy Dispersive a. Start a new Count Sheet for each sample X-ray Detector mounted on TEM column and to be analyzed. Record on count sheet: ana­ associated hardware/software to collect, lyst’s initials and date; lab sample number: save, and read out spectral Information, client sample number microscope identifica­ Calibration of Multi-Channel Analyzer shall tion: magnification for analysis; number of be checked regularly for Al at 1,48 KeV and predetermined grid openings to be analyzed: Cu at 8,04 KeV, as well as the manufacturer’s and grid identification. See the following procedures. Figure 4:

692

NYC-WTC_000390001

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000390001Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →