drilling the concrete slurry-' wall, 6) flagging operations in pit, and 7) while chipping
concrete with power tools during demolition activities at 7 WTC’s parking garage. Most
of the work areas u here app:trent overexposures to silica occuired were in the rubble
pile/pit; an area where OSHA continues to encourage the use of respiratory protection.
Organic
Compounds: OSHA has taken a total of 636 samples (excluding bulk and blank samples) for organic
compounds such as acetaldehyde, acrolein, aciy-'lonitrile, benzene, 2-butanone,
carbofurans, dioxin, PCBs, ethyl benzene, formaldehyde, Freon R-22
(chlorodiflouromethane), hexone, isocyanates (e.g. MDI, TDI), perchloroethylene,
polyTiuclear aromatics, phosgene, stxTene, toluene, 1-3 butadiene, trichloroethylene, vinyl
chloride, glutaraldehyde, and xylene. Screening samples initially showed elevated levels
of some organic chemicals resulting from the fires burning in the rubble pile. Subsequent
personal and area samples show worker exposure levels to be below OSH.-X limits.
However, one personal sample result for a benzene sample taken was found to be at the
8-hr. OSHA Allowable Limit concentration of 1 ppm. This was found on a backhoe
operator moving debris on 10/7/01. See information below for the specific counts in
regards to pohmuclear aromatics, Freon R-22, phosgene and dio.xin.
Dioxins: OSHA has taken 10 dioxin samples (excluding blanks) in the plume over hot spots in
(and around the perimeter of) the rubble pile. Dio.xin levels delected around the
perimeter are lower than those found directly over the pile. To date, only one sample
taken on the rubble pile showed dioxin levels which exceeded background levels.
Dioxins are considered collectively as suspect human carcinogens. OSH.A does not have
a PEL for dioxins.
Polynuclear Aromatic
Hydrocarbons OSHA has taken 110 samples (excluding blanks). The majority of the samples have not
showTi the presence of benzo(a)p\Tene and/or one or more of five additional fused
polycyclic hydrocarbons; anthracene, acridine, pyrene, chrysene and phenanthrene.
Sample results to date have identified eight samples which reached or exceeded OSH.A's
coal tar pitch volatile PEL of 0.2mg/m’. These personal samples were taken on the pile
on iron workers and grappler operators. OSH.-X continues to strongly recommend the use
of respiratory protection when working on the rubble pile.
Freon R-22,
Hydrogen Fluoride
& Phosgene; OSHA has taken a total of 202 samples for Freon R-22 (chlorodiflouromethane),
hydrogen fluoride, and phosgene. Onh' one Freon sample resulted in a detectable level of
6.4 ppm during the transfer of Freon from the auxiliary-' chiller, and all other samples were