NYC 9/11 Public Portal Document
materials. The organic analyses included
tests for the following pollutant chemi
8 cals: polycyclic aromatic hydrocarbons,
Downtown polychorlinated biphenyls, polycholori-
Hospital .
nated dibenzodioxins and other
hydrocarbons. Inorganic analyses of the
samples were completed to obtain infor
itobn-siji
mation on the amounts of various heavy
metahs and other inorganic materials
, present in the building materials, and in
C
the fire. The inorganic analyses included
tests for metals, ionic species, asbestos,
ll
XVBattejy and inorganic species. Finally, particle
\Y
Figure 1. Lower Manhattan'',
size analyses were conducted to provide
a general description of the sizes of
sites where WTC dusts these dust particles, which could be
were co llected by NYU breathed in and deposited in various
locations within the lung.
1,2,3.., The particle pollution that was
sample collection sites 9.12.01 released and then settled on surfaces
downwind of the WTC complex
A, B,C... included pulverized building debris,
samiple collection sites 9.13.01 and products of incomplete burning
produced by the explosion that ignited
the thousands of liters of jet fuel.
The products of incomplete burning
NTIT & Rutgers chemical analyses of WTC dust pollution were produced by the intense fire that
consumed many combustible materials
The explosion and collapse of the World provided information about community in the buildings including: furnishings,
Trade Center was a catastrophic event exposures to WTC pollution until the equipment, debris, wiring, metal, wood
that produced a particle pollution plume end of 2001 when the fires were finally etc. The amount of material deposited
impacting many workers, residents and extinguished. was extremely high,and in many indoor
commuters during the first few days The analyses conducted on each locations the deposited dust was thick.
after 9/11/2001. Researchers from both of the WTC dust samples were based In outdoor situations the settled dust and
NYU and Rutgers collected and upon the nature of the sources of the smoke was thick. The mass of the dust
analyzed samples of dust from the WTC particles. The force of the collapse samples was composed primarily of
plume. Samples of the total settled dust pulverized the two main WTC buildings construction materials, soot, and paint
and smoke were collected at locations and several adjacent low-rise buildings, (leaded and unleaded), and glass fibers
surrounding Ground Zero on September so the study includes analyses to detect (mineral wool and fiberglass).
12, 13, 16, and 17, and are representa construction and furnishing debris, and A small amount of asbestos was
tive of the material generated and settled combustible materials and products of found in the samples. The levels of lead
immediately after the explosion and fire. incomplete combustion associated with were similar to the levels found in
and the collapse of the two buildings. the fires in each building. typical urban soils. However, the actual
On Friday, September 14th, Organic analysis of the dust levels of dust and smoke deposited in
NYU established a continuous particle samples were conducted to determine individual buildings and businesses
air pollution sampling site at the NYU the chemical nature of the products of needs to be assessed for clean up based
Downtown Hospital on Beekman Street, incomplete combustion produced by the upon the total surface area of lead and
just blocks east of Ground Zero that fires and to identify any other organic asbestos. A systematic effort will be
4