NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 8 pages

Ambient air protocol, H.S. for Leadership & [name], 2003

Machine-extracted title · confidence 55%

Ambient air and dust sampling protocol for High School for Leadership & [name] (M 894).

NYC-WTC_000385871–000385878
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AMBIENT AIR AND DUST SAMPLING PROTOCOL for H.S. for Leadership and Public Services (M894) Psge 7 of 8

(.lllll *

In the event that any one sample result is unsatisfactory BOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and Implement the appropriate response action(s).

PCB WIPE SAMPLES

• First floor lobby - one sample, • Fifth floor hallway, near elevators - one sample. • Tenth floor hallway, near elevators - one sample.

All sample collected shall be analyzed utilizing the EPA 8081 method.

Results from samples collected shall be reported to BOE, UFT, School Principal and the PA consultant in 4 days from the day of sampling.

In the event that any one sample result is unsatisfactory BOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response actiGn(s).

HEAVY METAL AIR SAMPLES

• First floor lobby - one sample. • Fifth floor hallway, near elevators - one sample. • Tenth floor hallway, near elevators - one sample.

All sample collected shall be analyzed utilizing NIOSH 7300 method for Ai, Cd, Cr, Co, Cu, Fe, Mg, Mn, Mo, Ni, Zn and NIOSH 6009 method for Hg.

Results from samples collected shall be reported to BOE, UFT, School Principal and the PA consultant in 4 days from the day of sampling.

In the event that any one-sample result is unsatisfactory BOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The said! parties will assess the situation and implement the appropriate response action(s).

TVOCs AIR SAMPLES

• First floor lobby - one sample. • Fifth floor hallway, near elevators - one sample. • Tenth floor hallway, near elevators - one sample.

All sample collected shall be analyzed utilizing Hydrocarbon Scan (16+A&B) OSHA 7 method.

Results from samples collected shall be reported to BOE, UFT, School Principal and the PA consultant in 4 days from the day of sampling. I

CITY_21MC100_0 09214825

NYC-WTC_000385877

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000385877Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →