1/ I AVBIENT AIR AND DUST SAMPLiNG PROTOCOL for H.S. far Leadership and Public Senrices (M894) Page 5 of 9

’ Thirteeen floor Hallway - one sample

Dust bulk samples will be collected at the aforementioned locations and analyzed via Polarized Light Microscopy (PLM). In the event that in any of the above locations there is not sufficient amount of dust for bulk sampling and/or analysis will be noted as Not Sufficient Amount of Material for Testing (NSAMT)

In the event that any of PLM analysis detect more than 1% by weight of fiberglass. BOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The; said parties will assess the situation and implement the appropriate response action(s}.

LEAD SURFACE DUST

» First floor lobby outside auditorium - one sample.

Cafeteria - one sample.

• Auditorium - one sample.

Two random classrooms - one sample from each classroom

• Third floor Hallway - one sample

• Fifth floor Hallway - one sample

• Seventh floor Hallway - one sample

• Ninth floor Hallway - one sample

• Thirteen floor Hallway - one sample

Ail dust wipe samples taken shall be analyzed in accordance with EPA7082 method via Flame Atomic Absorption (FAA).

Dust wipe results shall be considered satisfactory when the levels obtained are below the EPA new level's for clearing a work area for re-occupancy after an EPA defined lead abatement is performed, as specified in 40 CFR §745.227(e)(8)(viii).

Floors: 40 micrograms of lead per square foot Window Sills: 250 micrograms of lead per square foot

Dust wipe results shall be considered unsatisfactory when the levels obtained are greater than the EPA new levels for clearing a work area for re-occupancy after an EPA defined lead abatement is performed, as specified in 40 CFR §745.227(e)(8)(viii).

Floors; 40 micrograms of lead per square foot Window Sills: 250 micrograms of lead per square foot

I Results from samples collected shall be reported to BOE, UFT, School Princioal and the PA consultant within 24 hours.

CITY_21MC100_0 09214823

NYC-WTC_000385875

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000385875Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →