ambient air and dust sampling protocol for PS/IS89M. Page 5 of 9

• First floor (Throughout) - Additional minimum of five (5) samples within classrooms where present. One sample shall be collected within every Pre-K and Kindergarten classroom where present.

• Second floor Hallways south end - one sample immediately after the last class.

Second floor Classrooms - Additional minimum of five (5) samples within classrooms where present. One sample shall be collected within every Pre-K and Kindergarten classroom where present.

• Third floor Classrooms - Additional minimum of five (5) samples within classrooms where present. One sample shall be collected within every Pre-K and Kindergarten classroom where present.

Fourth Floor Classrooms - Additional minimum of five (5) samples within classrooms where present. One sample shall be collected within every Pre-K and Kindergarten classroom where present.

• Fourth floor Hallways south end - one sample immediately after the last class.

• Outside Playground - three samples on playground surface after last class.

• Exterior Building Entrances - one sample on ground at exterior of north and south entrances to the school.

Dust bulk samples will be collected at the aforementioned locations and analyzed via Polarized Light Microscopy (PLM). In the event that in any of the above locations there is not sufficient amount of dust for bulk sampling and/or analysis will be noted as Not Sufficient Amount of Material for Testing (NSAMT)

In the event that any of PLM analysis detects more than 1% by weight of fiberglass, ATC shall immediately notify BOE representative Mr. Mohamed Hemida, the IJFT and the PA consultant. BOE shall notify the school principal, the school custodian and the plant manager. The said parties will assess the situation and implement the appropriate response action(s) immediately.

LEAD SURFACE DUST

• First floor hallway outside cafeteria ~ 2 samples.

Cafeteria - one sample.

• Gymnasium - one sample.

• Auditorium - one sample.

• Classroom with north side unit ventilators - one sample immediately after the last class.

• Classroom with east side unit ventilators - one sample immediately after the last class.

CITY_21MC100_0 09214655

NYC-WTC_000385812

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000385812Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →