NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 14 pages

PCDD/PCDF level determination report, NYC

Machine-extracted title · confidence 28%

Laboratory report detailing analyses for dioxins at client location, with project identifiers.

NYC-WTC_000383409–000383422
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Services, Inc. 1700 Elm Street. Suite 200 ^ace Analytical" REPORT OF: CHEMICAL ANALYSES Minneapolis, MN 55414 Phone: 612.607.1700 www.pacBlabs.com Fax: 612.607.6444

PROJECT: PCDDZPCDF ANALYSES DATE: March 6, 2002

ISSUED TO: ATC Associates REPORT N0:02-1053890 Attn: Mr. Jim Cohn 104 East 25th Street, 10th Floor New York. NY 10010

INTRODUCTION

This report presents the results from the analyses performed on four samples that were submitted by a representative of ATC Associates. The samples were analyzed for the presence or absence of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) using a modified version of USEPA Method 8290 as described below.

SAMPLE IDENTIFICATION

Client ID SamDle Type Date Received Pace ID

ATC-0207-89M-DX1 Wipe 02/08/02 103311742 ATC-0207-89M-DX2 Wipe 02/08/02 103311759 ATC-0207-89M-DX3 Wipe 02/08/02 103311767 ATC-0207-89M-DX4 Wipe 02/08/02 103311775

METHODOLOGY

Sample Extraction

Each sample was spiked with ’^C,2-labeled PCDD/PCDF internal standards (Table 1) and extracted with toluene in a Soxhlet extractor. The extract was quantitatively transferred to a Kuderna-Danish - concentrator, concentrated, and solvent exchanged to hexane. The hexane extract was then spiked with 2,3,7,8-TCDD-3^Cl4 enrichment efficiency standard (Table 1) and processed through the analyte enrichment procedures described below.

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

friohr''- CITY_21MC100_002880355

NYC-WTC_000383410

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000383410Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000382417

PACE report: PCDD/PCDF levels for ATC project at 104 East 25th Street.

Similar indexed content

NYC-WTC_000326628

Analytical lab report for PCDDs & PCDFs; city file reference.

Similar indexed content

NYC-WTC_000383373

PACE lab report for ATC project 19125-0297; overview of method 8290.

Similar indexed content

Compare copies and versions →