Mr. Bernard P. Orlan April 4. 2002
Air Sampling for Metals Page 2
P.S. 234 (Manhattan) ATC Project No. 15-19125-0279
'fhe Environmental Protection Agency (EPA) has set a screening level for hexavalent chromium
(the more toxic form) in air of 0.6 micrograms per cubic meter of air (ug/m’), this assumes a
continuous exposure for one year. These samples were analyzed for total chromium (trivalent
and hexavalent).
The EPA’s ambient air standard for lead (Pb) is 1.5 ug/m’ (three-month average).
Results
C'hromium (Cr) was the only metal detected m all four samples and in the blank. Lead (Pb) was
detected in two of the samples but not m the blank. Blank-correcting the Cr levels reduces the
concentration.s to below the limit of detection. The results are shown in the following table;
METALS IN AIR CONCENTRATIONS
March 19, 2002
Cr
LOCATION (ug/m ’) Pb
SAMPLE NO. (ug/m ’)* Blank-corrected (ug/m’)
Main Lobby / Ml 0.328 BDL* BDL
r* floor Hallway/
M2 0.306 BDL 0.271
West Playground/
M3 0.656 0.099 0.270
Roof/M4 0.484 BDL BDL
FieldTllank/MS 0.537
ug/sample BDL
* micrograms per cubic meter ** Below Detection I.imit
All of the blank-corrected cliromium concentrations are below the EPA screening level of 0.6
ug/m\
Die concentrations of Pb are below EPA standard of 1.5 ug/m^ (three-month average).
ATC appreciates the opportunity to provide this indoor air quality sen ice to the BOE. Please call
me at (212) 353-8280 extension 212 if you have any questions.
Sincerely,
'James R. Cohn, CIH, CSP
Flegional Manager , Industrial Hygiene Division
Attachment