NYC 9/11 Public Portal Document
Attn: Mr. Bernard Orlan Received: 2/16/02 4:30:00 PM
N.Y.C. Board of Education
28-11 Queens Plaza North ATC Group#; 6703
Long Island City, NY’ 11101 Analysis Date: 2/17/02
Fax: (212) 475-4122 Phone; (212) 477-8941
Project: NYC-BOE PS 234M Project#; 14584-1823
292 Greenwich St., New York, NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical Asbestos
Area Non ^i^bestos Structures Sensitivity Concentration
Sample Volume Analyzed Asb Type(s) O.Sfi-S Sfi (S/cc) (S/mm^) (S/cc) Notes
09 1920.00 0.0450 0 NoneDetected 0 0 0.0045 <22.24 < 0.0045
6703 -9
10 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045
6703 -10
11 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045
6703 -11
12 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045
6.703 -12
13 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045
6703 -IS
14 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045
6703 -14
15 1920.00 0.045 0 0 None Detected 0 0 0.0045 <22.24 <0.0045
6703 -15
ROMAN PEYSAKHOV MICHAEL A. GORYCKl, Ph.D.
Analyzed by; Approved by:
Disclaimer: The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel. This lab is only responsible
for data reported in structures/nmT This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This repon may not oe used to aam
product endorsement by NVLAP or any other agency of the U.S. Government. This reports relates only to the samples reported above. Quality control data .'including 95%
confidence limits and laboratory and analysis' accuracy and precision) is available upon request.
Accredited for NVLAP PLIvVTEM #101187-0, NY Stale ELAP #10879
CITY_21MC100_002878113