NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

TEM asbestos analysis, Stuyvesant H.S., Dec 2001

Machine-extracted title · confidence 45%

AHERA TEM asbestos analysis results for exterior/interior of building at Stuyvesant High School, Dec 2001.

NYC-WTC_000379000–000379002
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

.Attn: Mr. Bernard Otlan Received; 12/2S/01 6:00:00 PM N.Y.C. Board of Education 2S-11 Queens Plaza NonJi ATC Group #: 6220 Long Island City, NY 11101 Analysis Date; 12.C9/01 Fax; (2121 475-4122 Phone: (212)477-8941 Project: New Stuyvesant H. S. . 345 Chambers St, NY , NY Exterior and Interior of Building and Roof

Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos /Irea Ao„ HsZresros Structures Sensitivity Concentration Sample /oZume Analyzed Asb O.Sfi-5 5f, (S/CC) (S/mm-) (S/cc) /Votes 9 1952.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 6220 -9

10 1960.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 6220 -10

II 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 6220 - I I

12 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 6220 -12

13 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 6220-13

14 1944.00 0.0450 0 None Detected 0 0 , 0.0044 <22.24 <0.0044 6220 -14

15- 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 ' 6220 -15

16 1960.00 0.0450 0 None Detected, 0 0 0.0044 <22.24 <0.0044 6220 -16

I7 1960.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 6220 -17

18 1952.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 6220 -18

MARK PEYSAKHOV MICHAEL A. GORYCKI, Ph.D.

Analyzed by: rov

Disclaimer: The laboratory is not responsible for data reported in slnjctures/cc. which is dependent on volume collected by non-laboratory personnel. This lab is only responsible for data reported in stnictures/mm'. This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. This reports relates only to the samples reported above. Quality control data (including 95% confidence limits and laboratory and analysis' accuracy and precision) is available upon request

Accredited for MVLAP PLMfTEM #101187-0, NY Slate ELAP #10879

CITY_21MC100_002874467

NYC-WTC_000379001

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000379001Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000398821

Laboratory TEM data and asbestos analysis notes for New Stuyvesant High School project, Dec 2001.

Similar indexed content

NYC-WTC_000378859

TEM analytical data for air samples at New Stuyvesant High School; includes sample 1 details.

Similar indexed content

NYC-WTC_000398728

TEM asbestos analysis of exterior/interior air at New Stuyvesant HS, Dec 17, 2001.

Similar indexed content

Compare copies and versions →