NYC 9/11 Public Portal Document
Attn: Mr. Bernard Orlan Received: 12/19/01 9:00:00 PM
N.Y.C. Board of Education
28-11 Queens Plaza North ATC Group#: 6151
Long Island City, NY 11101 Analysis Date; 12/20/01
Fax: (212)475-4122 Phone: (212)477-8941
Project: New Stuyvesant H. S., 345 Chambers St., NY , NY
Exterior and Interior of Building and Roof
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical Asbestos
z4raa Non Asbestos Structures Sensitivity Concentration
Sample Volume Analyzed Asb T^yP^(5) O.Su-S 5ft (S/cc) (S/mm=) (S/cc) Notes
9 1960.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044
6151 -9
10 1968.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044
6151 -10
11 1928.00 0.0450 0 None Delected 0 0 0.0044 <22.24 <0.0044
' 6151-11
12 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044
6151 -12
13 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044
6151 -13
14 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044
6151 -14
15- 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044
6151 -15
16 1944.00 0.0450 0 None Delected 0 0 0.0044 <22.24 <0.0044
6151 -16
17 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044
6151 -17
18 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044
6151 -18
MARK PEYSAKHOV MICHAEL A. GORYCKI, Ph.D.
Analyzed by: Approved by:
7
Disclaimer The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel. This lab is only responsible
for data reported in structurss/mmt This report may not be reproduced, except in lull, without written approval by ATC Associates Inc. This report may not be used Io ciaim
product endorsement by NVLAP or any other agency of the U.S. GovemmehL This reports relates only to the samples reported above. Quality control data (including 95%
confidence limits and laboratoy and analysis' accuracy and precision) is available upon request
Accredited for NVLAP PLWTEM #101187-0, NY State ELAP #10879
CITY_21MC100_002874235