NYC 9/11 Public Portal Document
TEM Asbestos (air) Count Sheet
Client Name: NYC BOE Volume (liters): 1920
Lab Group #: 6975 Filter Type / Filter Area: MCE 385 mm"
Lab Sample #: 6 Grid Opening Size: 0.01124
Client Sample #: 06 Area Examined: 0.04496 mm-
GRID BOX: Magnification: 20,000
GRIDID: Accelerating Voltage: 100 KeV
# Grid Openings: 4 Analysis Date: 3/8/02
Analysis Performed By:
MARK PEYSAKHOV
GO. Structure Structure Type Length ID of Structure Norv EDS
(Nonadb
No F B C M >=05 M Chrys Amphibole Nonasb Ambig/ND
No Coord <5u Elements)
Struct = > 0.5u >5:1 Aspect Ratio Grid acceptance:
N = Positive diffraction pattern properties conforming to <50% undissolved filter, overlapped or folded Totals
laboratory identification criteria observed <10% particulate coverage >50% coverage ate
\= EDS spectrum conforming to laboratory
least 20 unfolded or overlapped grid squares <5% F B c M I >5p
holes or opaque areas
identification criteria observed Chi’ysotile
AMPHIBOLES Amphibole
F = Single Fiber Amosite
B = Bundle (<3 fibers <1 fiber diameter apart Crocidolite Ambiguous
C = Cluster (>3 Intersections) Anthophyllite Non-Asbestos
T remolite
M = Matrix Non-Identified
Actinolite
NSD = No Structures Detected
CITY_21MC100_000464207
NYC-WTC_000376111
OCR can misread numbers and units. Confirm readings against the page image before using them.