NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan March 15, 2002
Indoor Air Quality Assessment Page 4
P. S. 150M ATC Project No. 15-19125-0289
* The measurements made during this assessment were instantaneous readings, the NPAAQS is
a 24-hour average.
TVOC Concentrations
TVOCs were not detected anywhere inside the building (0.0 ppm). The outdoor TVOC
concentration was also 0.0 ppm.
OBSERVATIONS
During this assessment, ATC noted the following:
• There was construction work going on in the plaza;
• The school building was occupied at the time of the assessment;
• No smoke odor was detected in the building;
FINDINGS
Based on the real-time measurements, the following findings are presented:
1. Concentrations of CO, CO2 and TVOCs were within applicable standards and guidelines;
2. None of the indoor PM2.5 measurements were above the NPAAQS of 65 pg/m^. Seven (7)
of the indoor measurements were above the USEPA recommended PM2.5 concentration of
40 pg/m^ for sensitive individuals and children. All of the outdoor PM2.5 measurements
were below the NPAAQS of 65 pg/m^ but above the USEPA recommended PM2.5
concentration of 40 pg/m^ for sensitive individuals and children.
3. All of the temperature measurements were above the range of 68 to 75° F (at 50 percent
relative humidity) recommended by ASHRAE Standard 55-1992 during the heating season
(wintertime conditions).
4. Fifteen (15) measurements of relative humidity were below the ASHRAE recommended
range of 30 to 60 percent for occupant comfort.
It is our pleasure to provide these indoor air quality services to the New York City Board of
Education. If you have any questions about this report, please call (212) 353-8280, extension
211 or 212.
Sincerely, Reviewed by:
A TC ASSOCIA TES INC.
Yiannis Efstathiou James R. Cohn, CIH, CSP
Project Manager Regional Manager
Industrial Hygiene Division
Attachment
CITY_21MC100_002853509
NYC-WTC_000375516
OCR can misread numbers and units. Confirm readings against the page image before using them.