^ace Analytical_________ Method 8290 Analysis Results
Tel: 612-607-1700
Fax: 612- 607-6444
Client - ATC
Client’s Sample ID ATC-0416-234M-DX2
Lab Sample ID 103481321
Filename F20506B_06
Injected By MRO
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 04/16/2002
ICAL Date 05/04/2002 Received 04/23/2002
CCal Filename(s) F20506A_13 & F20506B_14 Extracted 04/30/2002
Method Blank ID BLANK-1606 Analyzed 05/07/2002 00:00
Native Cone EMPC LRL Internal ng’s Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3.7,8-TCDF ND — 0.0024 A 2,3,7,8-TCDF-13C 2.00 83
Total TCDF 0.0097 ---- 0.0020 J 2.3,7,8-TCDD-13C 2.00 77
1,2,3.7,8-PeCDF-13C 2.00 68
2,3,7,8-TCDD ND 0.0038 A 2,3.4,7,8-PeCDF-13C 2.00 68
Total TCDD 0.0077 0.0020 J 1,2,3,7,8-PeCDD-13C 2.00 64
1,2,3,4,7,8-HxCDF-13C 2.00 112
1,2,3,7,8-PeCDF ND 0.0100 1,2,3,6,7,8-HxCDF-13C 2.00 107
2,3,4,7.8-PeCDF ND 0.0100 2,3,4,6,7,8-HxCDF-13C 2.00 105
Total PeCDF ND 0.0100 1,2,3.7,8,9-HxCDF-13C 2.00 98
1,2,3,4,7,8-HxCDD-13C 2.00 107
1,2,3,7.8-PeCDD ND 0.0100 1,2,3,6.7.8-HxCDD-13C 2.00 103
Total PeCDD ND 0.0100 1,2,3,4.6,7.8-HpCDF-13C 2.00 100
1,2,3,4,7,8,9-HpCDF-13C 2.00 97
1,2,3,4,7,8-HxCDF ND 0.0100 1,2,3,4,6,7,8-HpCDD-13C 2.00 90
1,2,3,6,7,8-HxCDF ND 0.0100 OCDD-13C . 4.00 110 *
2,3,4,6,7,8-HxCDF ND 0.0100
1,2,3,7,8,9-HxCDF ND 0.0100 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.0100 1,2,3,7,8.9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.0100 2,3,7,8-TCDD-37CI4 0.20 83
1,2,3,6,7.8-HxCDD ND 0.0100
1,2,3,7,8,9-HxCDD ND 0.0100
Total HxCDD ND 0.0100
1.2,3,4,6,7,8-HpCDF ND 0.0100 Total 2,3.7,8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.0100 Equivalence: 0.000023 ng/m2
Total HpCDF ND 0.0100 (Using ITE Factors)
1.2,3.4,6,7,8-HpCDD ND 0.0100
Total HpCDD ND 0.0100
OCDF ND 0.0200
OCDD 0.0230 0.0200 J
LRL = Lower Reporting Limit
Cone = Concentration (Totals include 2,3.7.8-substituted isomers) I = Interference
EM PC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 02-1056601
REPORT OF LABORATORY ANALYSIS