NYC-WTC_000315482
ATC IAQ measurements at PS 234M for BOE.
13 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗ATC report documents in-situ IAQ measurements at PS 234M, requested by NYC BOE, June 2002.
NYC-WTC_000375133–000375136OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan June 27,2002 Indoor Air Quality Assessment Page 3 P. S. 234M ATC Project No. 15-19125-0279
Real-Time Environmental Measurements
ATC collected sixty (60) sets of real-time environmental measurements consisting of fifty (50) from inside the school building and ten (10) outdoors. All three floors of the school were surveyed. These results are described below.
Field data sheets are found in Attachment 1. Readings began at 07:00 AM and concluded after 12:30 P.M.
Temperature
Indoor dry bulb temperature measurements ranged from 72.1 °F to 75.9 °F. Seven (7) of the indoor measurements for temperature was below the range of 73 to 79°F (at 50 percent relative humidity) as recommended by ASHRAE Standard 55-1992 during the summer season. The outdoor temperature measurements were 76,9 and 78.1 °F.
Relative Humidity
The relative humidity indoors ranged from 50.1 percent to 57.4 percent. All of the indoor measurements for relative humidity were within the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity measurements were 80.3 and 81.2 percent.
Carbon Dioxide Concentration
Carbon dioxide concentrations indoors ranged from 96 ppm to 1391 ppm. Forty-nine(49) of the indoor measurements were within the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The maximum outdoor (background) CO2 concentration was 616 ppm. Therefore, the maximum acceptable level of CO2 at this location was 1316 ppm (background level + 700 ppm). The highest reading (1391 ppm) was recorded in Room 118 approximately at 11:00 AM. with 24 occupants. Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of CO2 indoors is occupant respiration.
Carbon Monoxide Concentration
Carbon monoxide concentrations indoors were 1 ppm for all readings. These concentrations were within the NPAAQS/ASHRAE guideline of 9 ppm. The outdoor CO concentrations were also 1 ppm for alt readings.
Respirable Particulates (PM2,5)
Respirable particulate concentrations* indoors ranged between 18 pg/m^ to 68 pg/m^ with an average approximately 32 pg/m^- Two (2) of the measurements collected indoors for respirable particulate concentrations were above the NPAAQS 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. Six (6) of the indoor measurements were above the USEPA recommended concentration of 40 pg/m^ for sensitive
CITY_21MC100_013428744
NYC-WTC_000375135
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000315482
ATC IAQ measurements at PS 234M for BOE.
13 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000372233
IAQ measurements collected June 26, 2002 at PS 234M.
13 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000397705
ATC IAQ measurements report for PS 234M; scope of work noted.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000370129
ATC IAQ field report page with location/date details.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000397719
ATC indoor air quality measurements reported for PS 234M; June 2002.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315467
ATC IAQ measurements report for BOE at PS 234M.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315456
ATC report of IAQ measurements at PS 234M for BOE.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000397685
ATC report of lAQ measurements conducted on June 18, 2002 for PS 234M as part of BOE program.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313964
ATC report of IAQ measurements at P.S. 89M, June 25, 2002, for school air quality evaluation.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314680
IAQ measurements report for PS 234M by ATC.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000372213
ATC IAQ measurements at PS 234M, June 24, 2002, BOE-requested.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000397301
IAQ measurements collected April 17, 2002 at PS 234M for BOE evaluation.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000315482
ATC IAQ measurements at PS 234M for BOE.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315350
ATC IAQ report letter accompanying measurements for P.S. 234M.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000397705
ATC IAQ measurements report for PS 234M; scope of work noted.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000315281
ATC IAQ measurements at PS 234M; part of BOE monitoring, May 30, 2002.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000372193
SCOPE OF WORK for indoor air quality testing at PS 234M.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000397685
ATC report of lAQ measurements conducted on June 18, 2002 for PS 234M as part of BOE program.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000315482
ATC IAQ measurements at PS 234M for BOE.
Similar indexed content
NYC-WTC_000372233
IAQ measurements collected June 26, 2002 at PS 234M.
Similar indexed content
NYC-WTC_000397705
ATC IAQ measurements report for PS 234M; scope of work noted.
Similar indexed content
NYC-WTC_000370129
ATC IAQ field report page with location/date details.
Similar indexed content
NYC-WTC_000397719
ATC indoor air quality measurements reported for PS 234M; June 2002.
Similar indexed content