NYC 9/11 Public Portal Document
Attn: Mr. Bernard Orlan Received: 5/18/02 5:00:00 PM
N.Y.C. Board of Education ATC Group#: 7788
28-11 Queens Plaza North Analysis Date: 5/18/02
Long Island City, NY 11101
Fax: (212)475-4122 Phone: (212)477-8941
Project: H.S. Of Economics And Finance
100 Trinity Place, New York, NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical Asbestos
/(/•efl Tyoii Asbestos # Structures Sensitivity Concentration
Sample f^olume Analyzed Asb Type(s) O.Sfi-S 5fi (S/cc) (S/ntm^) (S/cc) Notes
11 1800.00 0,0450 0 None Detected 0 0.0048
0 <22.24 <0.0048
7788 -8
12 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 < 0.0048
7788 -9
13 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
7788 -10
14 1800.00 0.0450 0 None Detected <22.24
0 0 0.0048 <0.0048
7788 -1/
15 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
7788 -12
16 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
778S -13
17 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
7788 -14
18 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
7788 -15
19 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
77SS ■/6
ROMAN PEYSAKHOV MICHAEL A. GORYCKI, Ph.D.
Analyzed by: Approved by;
Disclaimer: The laboratory is not responsible for data reported in structures/cc, which is dependent on volume coKdcted by non-laboratory personnel. Thislatfis only responsible
for data reported in structures/mm^. This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim
product endorsement by NVLAP or any other agency of the U.S. Government This reports relates only to the samples reported above. Quality control data (including 95%
confidence limits and laboratory and analysis’ accuracy and precision) is available upon request.
Accredited for NVLAP PLM/TEM #101187-0, NY State ELAP #10879