NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

Analytical results for ATC, 19125-0279

Machine-extracted title · confidence 36%

Analytical results for PCB, metals, PAH & cyanide in ATC project 19125-0279.

NYC-WTC_000373679–000373682
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Jan 07 02 05:02p PSC Rnalytical Services G109213667 p. 15

^scz INDUSTRIAL HYGIENE •EPA/NVtAP 101262-0 ■AIHAACCREDITATIONNO. 100439 •NC DENR 599 Analytical Results ENVIRONMENTAL TESTING •NY DOlWtLAC 1D303 • PA DEP 06-3S3 •NJ DEP 77020 • CT DPH PH-0238

ANALY ilCAL SERVICES for ATC Associates WorkOrder: RO1120273 Client Reference: 19125-0279: PCS, Metals, PAH & Cyanide i

Analyte Concentration Limit of Test Date Analyzed Detection Method /Analyst (ug) : (mg/m’) : (ppm) (UE)

Client ID: ATC-1211.234M-M6 Lab ID: -ISA Date Sampled 12/1 l/OI Matrix: Filter AirVol.(L): 1210 Aluminum <1 <0.000826 1 N7300 MCE 12/19/2001 TH Cadmium <0.2 <0.000165 0.2 N7300 MCE 12/19/2001 TH Chromium <0.2 <0.000165 0.2 N7300 MCE 12/19/2001 TH Cobalt <0.1 <0.0000826 0.1 N7300 MCE 12/19/2001 TH Copper . <0.2 <0.000165 0.2 N7300 MCE - • 12/19/2001 TH Iron <2 <0.00165 2 N7300 MCE 12/19/2001 TH Magnesium <1.3 <0.00107 1.3 N730O MCE 12/19/2001 TH Manganese <0.3 <0.000248 0.3 N7300 MCE 12/19/2001 TH Molybdenum <1 <0.000826 1 N7300 MCE 12/19/2001 TH Nickel <0.2 <0.000165 0.2 N7300 MCE 12/19/2001 TH Zinc <0.5 <0.000413 0.5 N7300 MCE 12/19/2001 TH

Client ID: ATC-l 211-234M-M7 Lab ID: -16A Date Sampled 12/11/01 Matrix: Filter AirVol.(L): 1200 Aluminum <1 <0.000833 1 N7300 MCE 12/19/2001 TH Cadmium <0.2 <0.000167 0.2 N7300 MCE 12/19/2001 TH Ctiromium <0.2 <0.000167 0.2 N730O MCE 12/19/2001 TH Cobalt <0.1 <0.0000833 0.1 N7300 MCE 12/19/2001 TH Copper <0.2 <0,000167 0.2 N7300 MCE 12/19/2001 TH Iron <2 <0.00167 2' N7300 MCE 12/19/2001 TH Magnesium <1.3 <0.00108 1.3 N730O MCE 12/19/2001 TH Manganese <0.3 <0.000250 0.3 N7300 MCE 12/19/2001 TH Molybdenum <1 <0.000833 1 N7300 MCE 12/19/2001 TH Nickel <0.2 <0.000167 0.2 N73D0 MCE 12/19/2001 TH Zinc <0.000417 0.5 N7300 MCE ’ . 12/19/2001 TH

Client ID; ATC-l 21 I-234M-MS Lab ID: -17A Date Sampled: 12/1 l/OI Matrix: Filter Air Vol.(L): 1200 Aluminum <1 <0.000833 1 N7300 MCE 12/19/2001 TH Cadmium <0.2 <0.000167 0.2 N7300 MCE 12/19/2001 TH Chromium 0.23775 0.000198 0.2 N7300 MCE 12/19/2001 TH Cobalt <0.1 <0.0000833 0.1 N7300 MCE 12/19/2001 TH Copper <0.2 <0.000167 0.2 N7300 MCE 12/19/2001 TH Iron <2 <0.00167 2 N7300 MCE 12/19/2001 TH Magnesium <1.3 <0.00108 1.3 N7300 MCE 12/19/2001 TH Manganese <0.3 <0.000250 0.3 N7300 MCE 12/19/2001 TH Molybdenum <1 <0.000833 1 N7300 MCE 12/19/2001 TH Nickel <0.2 <0.000167 0.2 N7300 MCE 12/19/2001 TH Zinc <0.5 <0.000417 0.5 N7300 MCE 12/19/2001 TH

Page 5 of 11

CITY_2IMCl0 0_0 00462430 NYC-WTC_000373681

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000373681Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →