NYC 9/11 Public Portal Document
INDUSTRIAL HYGIENE ENVIRONMENTAL TESTING
•EPAWLAP 101262-0 • NYOOWNELAC 10803 • NJ DEPPA020
•AIHAACCREDITATIONNO. 100439 • PA OEP 06-353 •CT DPH PH-0238
•NCDENR 599
ANALYTICAL SERVICES Analytical Results
for
ATC Associates
WorkOrder: R02050418
Client Reference: 19125-0279, Metals
Analyte Concentration Limit of Test Date Analyzed
Detection Method /Analyst
(«e) ; (iiig/m") • (ppm) (ug)
Client ID: A rC-0507-234M-M5 7'Z- Lab ID: -05.A Date Sampled: 5/7/02 Matrix: Filter Air Vol.(L); NA
Aluminum <1.00 1 N7300 MCE 05/16/2002 AJB
Cadmium <0.200 0.2 N7300 MCE 05/16/2002 AJH
------- Chromium 0.970 0.2 N7300 MCE 05/16/2002 AJB
Cobalt <0.100 0.1 N7300 MCE 05/16/2002 AJB
Copper <0.200 0.2 N7300 MCE 05/16/2002 AJB
Iron <2.00 2 N7300 MCE 05/16/2002 AJB
.ead 0.355------- 0.3 N7300 MCE 05/16/2002 AJB
Magnesium <1.30 1.3 N7300 MCE 05/16/2002 AJB
Manganese <0.300 0.3 N7300 MCE 05/16/2002 AJB
Molybdenum <1.00 1 N7300 MCE 05/16/2002 AJB
NicKel <0.200 0.2 N7300 MCE 05/16/2002 AJB
Zinc <0.500 0.5 N7300 MCE 05/16/2002 AJB
ClkiitlD: ATC-0J07-234M-M6 V 7 J Lab ID: -06/\ Date Sampled: S/7/02 Matrix: Filter Air Vol.(L); N.A
Aluminum <1.00 1 N7300 MCE 05/16/2002 AJB
Cadmium <0.200 0.2 N7300 MCE 05/16/2002 AJB
Chromium 0.456 0.2 N7300 MCE 05/16/2002 AJB
Cobalt <0.100 0.1 N7300 MCE 05/16/2002 AJB
Copper <0.200 0.2 N7300 MCE 05/16/2002 AJB
iron <2.00 2 N7300 MCE 05/16/2C02 AJB
■ead 0.376----- 0.3 N7300 MCE 05/16/2002 AJB
Magnesium <1.30 1.3 N7300 MCE 05/16/2002 AJB
Manganese <0.300 0.3 N7300 MCE 05/16/2002 AJB
Molybdenum <1.00 1 N7300 MCE 05/16/2002 AJB
NicKel <0.200 0.2 N 7300 MCE 05/16/2002 AJB
.Zinc 1.57 0.5 N7300 MCE 05/16/2002 AJB
/a) Analysis indicates possible breakthrough; back section result is greater than 0% of the front section result.
General Notes:
<: Less than the indicated limit of detection (LOD).
Information not available or not applicable.
Back sections were checked and showed no significant breakthrough.
Page 3 of 3
CITY_21MC100_002867606
NYC-WTC_000371767
OCR can misread numbers and units. Confirm readings against the page image before using them.