Mr. Bernard P. Orlan May 8,2002 Air Sampling for Metals Page 2 P.S. 234 (Manhattani ATC Proiect No. 15-19125-0279

The Environmental Protection Agency (EPA) has set a screening level for hexavalent chromium (the more toxic form) in air of 0.6 micrograms per cubic meter of air (ug/m’), this assumes a continuous exposure for one year. These samples were analyzed for total chromium (trivalent and hexavalent).

The EPA’s ambient air standard for lead (Pb) is 1.5 ug/m’ (three-month average).

EfisuUs Chromium (CY) was the only metal detected in all four samples and in both blanks. Lead (Pb) was detected in all of the samples and in one of the blanks. Aluminum (Al) and Lead (Pb) were detected in all of the samples. Iron (Fe) was detected in three samples but not in the blanks. Blank-correcting the Cr levels reduces the concentrations to below the limit of detection. The results are shown in the following table:

METALS IN AIR CONCENTRATIONS Apri 16,2002 Cr LOCATION AI Cr , (ug/m’) Pb SAMPLE NO. (ug/m’) (ug/m’) Blank-corrected (ug/m^ (ug/m’)

Main Lobby / Ml 1.74 0.390 *BDL 3.37 0.316 P‘ floor Hallway / M2 1.34 0.378 BDL BDL 0.288 West Playground/ M3 1..3 0.299 BDL 2.09 0.313 Roof/M4 1.4 0.572 BDL 2.11 0.353 Field Blank / M5 BDL *-» 0.348 .342 ug/sample BDL ug/sample Field Blank / M6 0.558 BDL ug/sample BDL BDL * Below Detection Limit

All of the blank-corrected chromium concentrations are below the EPA screening level of 0.6 ug/m\

The concentrations of Pb are below EPA standard of 1.5 ug/m’ (three-month average).

The EPA has no screening level or standard for iron in ambient air.

CITY_21MC100_002867581

NYC-WTC_000371746

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000371746Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →