Lab report, World Trade Center-5 air sample, Sept 2001

Machine-extracted title · confidence 42%

Air/gas sample from Broadway Ave & 31st St, Queens; aluminum measured, World Trade Center-5 project.

NYC-WTC_000368453–000368466
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

HEUNhAULT ASSOCIAT ES, INC. NYCDEP - WTC 631-467-8477 Z z 5-BORO SAMPLING ■<

o METALS IN AIR o co

I io jCALCULATION FOR OSHA 1D121/125G - METALS IN AIR VIA CASSETTE FILTER (37MM MILLIPORE) & MOBILE VACUUM PUMPS jA= Concentration of Analyte in sample solution (pg/ml) or (mg/L) J ■0 c o o I CT o j B=Concentration of Blank in sample solution (|ig/ml) or (mg/L) o' o CJ> 00 jSSV= Sample Solution Volume ASSV= Analyte concentration x Sample Solution Volume AR= (A X SSV) - (B X BSV) I "0 o C3> ro ■BSV=Blank Sample Volume BBSV=Blank concentration x Blank Sample Volume AV I 03

,RAB= Reagent Blank Concentration (pg/ml) or (mg/L) O o o !rABSV= Reagent Blank Sample Volume 1 c 3 5 D= Dilution Factor (NONE) CD I 3

Ino GRAVIMETIC FACTORS For the Trip Blank Analytical Value: IAV= Air Volume Sampled AR= (B X BSV) - (RAB X RABSV) I IAR=Analytical Result AV I I ARR=Analytical Reportable Result in mg/m’ (rounded off to 3-sigma)

r A (mg/L) SSV (mL) A X SSV = ASSV B (mg/L) BSV (mL) B X BSV = BBSV ASSV -BSSV = AR AV Liters AR/AV ANALYTE ARR mg/rn’ 0.093 100 9.3 0.092 100 9.2 0.1 30 0.0033333 Aluminum- Al <0.01 100 4.6 0.035 100 3.5 1.1 30 0.0366667 Antimony-Sb 0.03 100 -0.7 -0.012 100 -1.2 0.5 30 0.0166667 Arsenic-As 0.02 0.002 100 0.2 0.002 100 0.2 0 30 0 Barium-Ba <0.01 100 0 100 0 0 30 0 Beryllium-Be <0.01 ""o’oo'f' 100 0.1 ""‘0.061' 100 0.1 0 30 0 Cadmium-Cd <0.01 "■■6"379^“ 100 37.9 0.‘752 100 75.2 -37.3 30 -1.2433333 Calcium-Ca <0.01 ■■■■6‘.666"~ 100 0.6 ■""0.069 100 0.9 -0.3 30 -0.01 Chromium-Cr <0.01 ■■"6’.’668"~ 100 0.8 ■""o.’()i2 100 1.2 _________ 211 30 -0.0133333 Copper-Cu <0.01 ■■■■6‘.'o1b5"' 100 ■■■■'0.052 8.5 100 5.2 3.3 30 0.11 Iron-Fe 0.11 ■■■■o'.ooz” 100 0.2 0.002 100 0.2 0 30 0 Lead-Pb <0.01 "■”6'6'7"" 100 7 o'Tse 100 15.8 ____________ -8.8 30 -0.2933333 Magnesium-Mg <0.01 ""o'.'o'se”' 100 5.6 ■■■■■6"66i' 100 6.1 -0.5 30 -0.0166667 Manganese-Mn <0.01 100 100 30 Mercury-Hg <0.01 o 0.001 100 0.1 0.001 100 0.1 0 30 6 Nickel-NI <0.01 H K ■q'TsV 100 13.1 ■’o'Tae 100 13.6 -0.5 30 -0.0166667 Potassium-K <0.01 I to ■o.oi9" 100 1.9 ■6"665 100 0.5 1.4 30 0.0466667 Selenium-Se 0.05 s O ■o’ooV ■L883' 100 100 0.1 188.3 ■6"66i' ■"Z22 100 100 0.1 222 0 -33.7 30 0 Silver-Ag 30 -1.1233333 Sodium-Na 0.01 <0.01

I o o ■-■6?6o4 100 -0.4 -o.'6rr 100 -1.1 0.7 30 0.0233333 Thallium-TI 0.02 o ■d’ois" 100 1.9 "o'.oi'o' 100 1.9 0 30 0 Zinc-Zn <0.01

o LAB ID #01090387-005

o NYCDEP -ATLANTIC AV & SMITH STR. BROOKLYN c;/JEM FILES/NYCDEP-HAZMAT/01090387.xls

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000368462Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →