z ■< PEDNEAULT ASSOCIATES, INC. NYCDEP - v\rrc z ■<

o 631-467-8477 5-BORO SAMPLING - o io fCALCULATION FOR OSHA lD12 V12^^gMET^ IN AIR VIA^SmE FILTER (37MM MILUPORE) & MOBILE VACUUM PUMPS METALS IN AIR co

I ■D o c o jA= Concentration of Analyte in sample solution (pg/ml) or (mg/L) CT o o I o' CJ> jB=Concentration of Blank in sample solution (pg/ml) or (mg/L) ■D 00 o o GO jSSVo* Sample Solution VoIume ASSV" AnaIyte concentration x Sample Solution Volume AR= (A X SSV) - (B X BSV) I 3. o 03 ■BSV»BlanIc Sample Volume BBSV»BIank concentration x Blank Sample 'Volume AV I o !rAB= Reagent Blank Concentration (pg/ml) or (mg/L) o o c ! RABSV= Reagent Blank Sample Volume I 3 CD O ■d- Dilution Factor (NONE) I Ino GRAVIMETIC FACTORS For the Trip Blank Analytical Value: IAV= Air Volume Sampled AR= (B X BSV ) - (RAB X RABSV) I IAR=Analytical Result AV I I I IA^=AnJytical Ecpcjrt^lc_ResnltJo -__________________ J

A (mg/L) - SSV(mL) A^ SSWASSV ?BSV;(mL) BXBSVg^BBSV ASS\^BSSV = AR AV LIters O^naLytes** r{BARRIng/rr® 0.083 100 8.3 0.069 100 6.9 1.4 30 0.0466667 Aluminum- Al 0.05 '0.039' 100 3.9 ■o.'d25 100 2.5 1.4 30 0.0466667 Antimony-Sb 0.05 “'oroTf 100 -1.1 ^0015 100 -1.5 0.4 30 0.0133333 Arsenic-As 0.01 -0005" 100 0.5 ■d.'o'63' 100 0.3 0.2 30 0.0066667 Barium-Ba <0.01 ■^iT 100 -1.1 -d.'o'iT 100 -1.1 0 30 0 Beryllium-Be <0.01 '■6?O21'' 100 -2.1 ■d.02l' 100 -2.1 0 30 0 Cadmium-Cd <0.01 "i's'os" 100 150.3 'Tses' 100 136.8 13.5 30 0.45 Calcium-Ca 0.45 I- '0.007' 100 0.7 "dooe 100 0.6 0.1 30 0.0033333 Chromium-Cr <0.01 I. "■6?O55 100 -5.5 “djos 100 -5 -0.5 30 -0.0166667 Copper-Cu <0.01 "o'Toe" 100 10.6 ■004? 100 4.1 6.5 30 0.2166667 Iron-Fe 0.22 '■■o"oi'i" 100 -1.1 ^0013 100 -1.3 0.2 30 0.0066667 Lead-Pb <0.01 "o'.225" 100 22.5 '022? 100 22.1 0.4 30 0.0133333 Magnesium-Mg <0.01 "aoss" 100 8.3 ■dOB8 100 8.8 -0.5 30 -0.0166667 Manganese-Mn <0.01 o 100 100 30 Mercury-Hg <0.01 H ['"'doos 100 0.3 0.002 100 0.2 0.1 30 0.0033333 Nickel-NI <0.01 K I to i""o'6'62' 100 66.2 ■deeT 100 66.1 0.1 30 0.0033333 Potassium-K <0.01

I o i""o'b'i4 i""'b'.'o'9' i 0648 100 100 100 1.4 -9 364.8 ■ddis ~-d'09 ■aTts 100 100 100 1.5 -9 417.3 -0.1 0 -52.5 30 -0.0033333 Selenium-Se 30 30 0 Silver-Ag -1.75 Sodium-Na <0.01 <0.01 <0.01 o Io o i""-o66T 100 -0.1 100 -0.3 0.2 30 0.0066667 Thallium-TI <0.01 •""‘dos' 100 5 '"6?b'3' 100 3 2 30 0.0666667 Zinc-Zn 0.07 CO CR LAB ID #01100280-005 CO NYCDEP -ATLANTIC AV & SMITH STR. BROOKLYN

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000368330Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →