NYC-WTC_000420968
Permit-related correspondence regarding exterior facade cleaning and condo unit considerations.
5 shared non-person entities · 1 shared topics · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗Data summary of asbestos air and debris testing at 250 [name] Avenue; TEM results listed by location.
NYC-WTC_000367208–000367210OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
RY Management - WTC Asbestos Air & Debris Testing Hudson View East - 250 South End Avenue Data Summary Apt. # or Matrix Analytical Results Asbestos Date Sample ID Area Tested Hallway (Air/Bulk) Method (Pos./Neg.) Type Bedroom Window 9/28/01 1 15D Bulk TEM Pos Chrysotile Sill Liv. Room Window 9/28/01 2 15D Bulk TEM Pos Chrysotile Sill 9/28/01 3 6C Liv. Room Floor Bulk TEM Neg n/a 9/28/01 4 16D Liv. Room Win. Sill Bulk TEM Neg n/a Master Bedroom 9/28/01 5 16D Bulk TEM Neg n/a Win. Sill ‘ND=none detected
CITY_DEP_WORBY_CANNATA_SUBP_000004032
NYC-WTC_000367209
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000420968
Permit-related correspondence regarding exterior facade cleaning and condo unit considerations.
5 shared non-person entities · 1 shared topics · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000230980
Application submitted to the DEP regarding cleaning procedures for a residential condominium, including exterior facade and interior duct work.
5 shared non-person entities · similarity 0.934
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409056
Air/bulk sample data summary for 17 Battery Place building floors in Apr 2002.
1 shared non-person entities · similarity 0.928
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409063
Analytical data showing TEM results on multiple floors with detected asbestos.
1 shared non-person entities · similarity 0.925
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409059
Data summary page listing floor-by-floor TEM results for multiple levels.
2 shared non-person entities · similarity 0.913
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000421064
Lab report memo requesting FEMA funds to cover washdown/cleaning of AMEX Building, 200 Vesey, Jun 2002.
3 shared non-person entities · similarity 0.910
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000366571
Pace University air sampling report addressing asbestos concerns and testing in Pace Plaza.
1 shared non-person entities · 1 shared topics · similarity 0.909
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121061
Laboratory report from EMSNY detailing air sampling results for 250 South End Avenue conducted in September 2001.
5 shared non-person entities · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000339095
Consulting-supplied bulk and surface asbestos results from various sites (Bronx, office walls).
2 shared non-person entities · 1 shared topics · similarity 0.917
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
3 shared non-person entities · similarity 0.916
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000098015
Record of a completed hearing and penalty assessment for an environmental violation at 65 Nassau Street.
2 shared non-person entities · similarity 0.910
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000108678
Document page summarizing positive and negative counts for asbestos analysis via PLM, PCM, and TEM methods.
3 shared non-person entities · similarity 0.909
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000420968
Permit-related correspondence regarding exterior facade cleaning and condo unit considerations.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121061
Laboratory report from EMSNY detailing air sampling results for 250 South End Avenue conducted in September 2001.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000230980
Application submitted to the DEP regarding cleaning procedures for a residential condominium, including exterior facade and interior duct work.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000230980
Application submitted to the DEP regarding cleaning procedures for a residential condominium, including exterior facade and interior duct work.
Similarity score 0.979 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121061
Laboratory report from EMSNY detailing air sampling results for 250 South End Avenue conducted in September 2001.
Similarity score 0.978 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000420968
Permit-related correspondence regarding exterior facade cleaning and condo unit considerations.
Similarity score 0.978 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Laboratory report from EMSNY detailing air sampling results for 250 South End Avenue conducted in September 2001.
Similar indexed content
NYC-WTC_000420968
Permit-related correspondence regarding exterior facade cleaning and condo unit considerations.
Similar indexed content
Application submitted to the DEP regarding cleaning procedures for a residential condominium, including exterior facade and interior duct work.
Similar indexed content
Air/bulk sample data summary for 17 Battery Place building floors in Apr 2002.
Similar indexed content
Analytical data showing TEM results on multiple floors with detected asbestos.