Asbestos TEM Analysis, Tribeca 105, 2001-2002

Machine-extracted title · confidence 30%

TEM asbestos analysis report for Tribeca site, 2001-2002.

NYC-WTC_000365374–000365418
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

ATC Associates Inc. Approved N.Y. State ELAP #10879 104 East 25th Street ACCREDITED NVLAP Lab Code # 1187 New York, NY lOOlG Report Date: 10/25/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identif by Selected-Area Electron Diffraction (SAED’ and Energy-Dispersive X-RAY Spectroscopy ;EDS> Method; ARE PA Final Rule, ERA Federal Register (40 CFR, Part 76 •No. 21J, October 30, 1987

Sample Iderxificacion Analysis Parameters

Projecc/Sit- ibeca, 105 Duane St., NY, NY TE.M Sample No. : 5762 62244 Various Sites Date Received; /01 Grid Openings Analyzed:__ 6

Project Sample No.: 30 Average Grid Opening: 106.00 um

Air Volume:^130C ers Total Area Analyzed: 0.0674 mrn2

Filter Type: MCE 25 mn diam., Pore Size: 0.45 um Analytical Sensitivity: 14.8 s,/mm2 Effective Area; 335mm2 0 . 0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total Struct. Filter Air Fibers Bundles Clusters Struct Struct -> = Sum Struct/mnt2 Struct/cc nam/m3

Chrysotile Asbestos 0 0 0 0 C,0 c. cm 0

Amphibole Asbestos 0 0 1 0 0.0 0.0000 u

Ambiguous C 0 0 0.0 0 . 0000 0

Total asbestos (includes ambiguous structures; 0 0.0 0 . 0000 0 Non-Asbestos 0 0 0 0 0.0 0 . 0000 N/A No Identification 0 0 0 0 0.0 0 . 0000 N/A

Totals '.All Structures' 0 0.0 0.0000 N/A The estimated uncertai of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type; None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by; Report Reviewed by:

Roman Peysakhov Mrcnael A. Gorycki, Ph.D. rector or Electron Microscopy

CITY_21MC100_002849042

NYC-WTC_000365399

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000365399Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000365476

Asbestos TEM analysis results for Tribeca Towers sample 5761; 1300 L air volume.

Similar indexed content

NYC-WTC_000365560

TEM analysis results for Tribeca Towers, sample 5770 with opening and area details.

Similar indexed content

NYC-WTC_000365640

TEM analysis details for Tribeca Towers sample set 5771 series with diffraction and EDS data.

Similar indexed content

NYC-WTC_000365613

TEM analysis details for Tribeca Towers, sample H-1 with diffraction and EDS data.

Similar indexed content

Compare copies and versions →