NYC 9/11 Public Portal Document
ATC Environmental, Inc.
104 East 25th Street
New York, New York 10010
ATC Associates Inc. Approved N.Y. State ELAP #10879
104 East 25th Street ACCREDITED NVLAP Lab Code # 1187
New York, NY 10010 Report Date: 10/12/01
ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS)
Method- AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol 52, No 210, October 30, 1987
Sample Idencxfication Analysis Parameters
Pro3ecc/Sxte 99 Church Street, 99 Church St , NY, NY TEM Sample No 5670 - 60955
Lobby
Date Received. ]^/l^/01 Grid Openings Analyzed __ 4
Project Sample No • L-5 Average Grid Opening 106 00 um
Air Volume 1800 liters Total Area Analyzed 0 0450 mm2
Filter Type MCE 25 mm diam , Pore Size Q 45 um Analytical Sensitivity 22 2 s/mm2
Effective Area 385 mm2 Q 0048 s/cc
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matrix Total Struct Filter Air
Fibers Bundles Clusters Struct Struct > = 5um Struct/mm2 Struct/cc ncjm/mJ
Chrysotile Asbestos 0 0 0 0 0 0 0 0 0 0000 0
Amphibole Asbestos 0 0 0 0 0 0 0 0 0 0000 0
Ambiguous 0 0 0 0 0 0 0 0 0 0000 0
Total asbestos (includes ambiguous structures) 0 0 0 0 0.0000 0
Non-Asbestos 0 0 0 0 0 0 0.0 0 0000 N/A
No Identification 0 0 0 0 0 0 0 0 0 0000 N/A
Totals (All Structures) 0 0 0 0 0 0000 N/A
The estimated uncertainty of this analysis is 1 standard deviation
Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
Analyzed by. Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
CITY_21MC100_002842227
NYC-WTC_000364606
OCR can misread numbers and units. Confirm readings against the page image before using them.