ATC Environmental, Inc. 104 East 25th Street New York, New York 10010 N.Y.C. School Construction Authority Approved N.Y. State ELAP #10879 30-30 Thomson Avenue ACCREDITED NVLAP Lab Code #118 Long Island City, NY 11101 Report Date: 10/04/01 ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) with Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHBRA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, Ho. 210, October 30, 1987

Sample Identification Analvais Parameters

Project/Site: Stuwesant H.S., 345 Chambers St., NY, WY TEM Sample No.: 5595 - 59936 Floors 2-5, Escalators Date Received: 10/03/01 Grid Openings Analyzed:_ 4

Project Sample No.: SHS-2>5.E-10/3-04 Average Grid OpeniiKc 106.00 um

Air Volume: 1863 liters Total Area Analyzed: 0.0450 imi2

Filter Type; MCE 25 mra diam., Pore Size: 0.45 um Analytical Sensitivity: 22.2 8/inm2 Effective Area; 385 nim2 0.0046 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. struct. Filter Air Fibers Bundles Clusters Struct. Struct. >«5uin Struct/inm2 Struct/cc ncnn/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

An^hibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbeatos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation. ■ .-Yoj

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected Hi The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the meth

Analyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_DEP_WORBY_CANNATA_SUBP_000001715

NYC-WTC_000364320

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000364320Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270753

TEM analysis report for New Stuyvesant High School building exterior and interior, 10/24/01.

Similar indexed content

Compare copies and versions →