NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 8 pages

Chain of Custody form for NOB sample analysis, 2002

Machine-extracted title · confidence 42%

Chain-of-custody guidance for non-friable organically bound material samples; procedures and signatures.

NYC-WTC_000363429–000363436
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

EMSLNYCNOBCHTFIELDSOP 200.0 Revison 1 February, 2002

6.0 DEFINITIONS:

Working Magnification: The magnification at which analysis should be performed.

Fiber Criteria: The attributes, size and shape, that a structure must display in ' order to be counted.

Sizing of Fibers: How the size of a structure needs to be recorded on the worksheet. For AHERA. a check is placed in a column according to a structure being < or > Sum length. For EPA Level II, the actual length and width will need to be recorded.

Reguired EDX: The frequency at which structures need to be analyzed by EDX. For AHERA, each structure, which will cause the sample to exceed 70str/mm2 will need EDX analysis. In the case of AHERA samples, this usually equates to the first four structures. For the analysis of water under 100.2, The x-ray spectrum for each type of asbestos observed for each set of samples from the same source or a minimum of every fifth sample analyzed must be recorded.

Reguired Diffraction Patterns: The frequency at which structures need to be analyzed by SAED. •

Stopping Rules: The criteria required before analysis can be suspended.

Required Analytical Sensitivity: The criteria required for the number of grid openings to be analyzed. AHERA requires an A.S. of 0.005str/cc so a sample with 1200 liters being analyzed on 0.0129 mm^ grid opening will require 5 openings for analysis.

Laboratory Blanks: A blank filter supplied by the lab, which is prepped along side of the samples to test for contamination. This section states if a laboratory blank is required and if the blank will need to. be analyzed at the time of sample analysis.

Reguired Filters: The type of filter that the sample is to be taken on or filtered through.

Pass / Fail Limit: The level or concentration at which a sample or set of samples is past acceptable limits.

Quality Control: The steps to follow for QC. (S= Intra Analyst; D= Inter Analyst; SR=lntra Analyst Reprep. DRI=lnter Analyst Reprep, Inter Laboratory; V= Verified. B=Blanks).

Controlled Copy Page 7 of 7

CITY_21MC100_002848039

NYC-WTC_000363436

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363436Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →