=»= TESTWELL LABORATORIES, INC. Environmental Laboratory NYS EUP i 11142

47 Hudson Street, Ossining, New York 10562 NVLAP J 200083-0 AIHA # 100147

PCM AIR SAMPLE RESULTS Client: Bovis Lend Lease Date Collected: 05/14/02 Date Rec'd (lab): 05/15/02 Project #: MBO-025AB Analysis Date: 05/16/02 Analyst: D. McCar/ Sample Location Millenium Hilton @ WTC 55 Chruch Street Analytical NIOSH 7400 New York, New York Various Floors Sample Condition Acceptable? YES Field Technician T. Chhetry

Sample Concentration Sample #: Sample Location: 02PCM S Volume Type f/cc

Outside Work Area Clean Room of 61 During 12650 1200 <0.0023 Remote Personal Decon Outside Work Area Remote V/aste 62 During 12691 1200 <0.0023 Decon Outside Work Area 56th Floor Inside 63 During 12692 1200 0.0074 Airlock Outside Work Area 56th Foor 64 During 12693 1200 0.0059 Elevator Lobby Outside Work Area 55th Floor Inside 65 Airlock During 12694 1200 0.0039

Outside Work Area 55th Floor 66 During 12695 1200 0.0041 , Elevator Lobby Outside Work Area 54th Floor Inside 67 During 12696 1200 0.0051 Airlock Outside Work Area 54th Floor 68 During 12697 1200 0.0049 Elevator Lobby Outside Work Area 53rd Floor Inside 69 During 12698 1200 0.0106 Airlock Outside Work Area 53rd Foor 70 During 12699 1200 0.0114 Elevator Lobby Outside Work Area Clean Room of 71 During 12700 1275 0.0023 Remote Personal Decon Outside Work Area Remote Waste 72 During 12701 1275 <0.0021 Decon • Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95% confidence level at 2 standard deviations. ** Sample information is provided by the client & presented as stated. *** Laboratory QC data available upon request. *’** The laboratory has no control over air sampling collection. Reports are the confidential property of our clients. This certificate of analysisfreport shall not be used by the client to claim product endorsement by the National Voluntary Laboratoiy Approval Program (NVLAP) or any agency of the United States Government. This ce.hificate of analysis/report shall not be reproduced except in full, without the written approval of Testwell Laboratories. Inc.

Deborah McCah - Laboratory Director

Page 1 of 1

CITY_21MC100_002858403

NYC-WTC_000363218

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363218Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →