FEMA/EPA DEP WTC dust clearance report

Machine-extracted title · confidence 42%

Lab results and narrative describing DEP/EPA/FEMA collaboration and dust clearance for WTC buildings.

NYC-WTC_000363056–000363059
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Additionally, asbestos containing materials (ACMs), such as floor tiles, were observed during DEP’s cleaning of the building. Some of the ACMs may be present under the hardwood flooring, thus samples collected from this location may be more representative of the building materials contained within the building rather than indicating contamination from other sources.

It should also be noted that several errors were detected in the calculation of sample concentrations. Two samples had incorrect concentrations reported, samples 221160-02 and 221160-03 (reported on page 6 of the report) should have reported concentrations of 1,471,401 and 432,765 s/cm^, respectively.

Mold and Bacteria Data

Based upon the results that were received, it appears that one sample was collected for mold and bacteria from a kitchen floor and counter on the third floor. The sample was analyzed by P&K Microbiology Services, Inc. with the number and type of fungi and bacteria being counted and identified. Seven fungi species were identified with the highest count for any one species being 900 colony forming units/square inch (CFU/in^ ) and a total sum of 2,200 CFU/in\ while six bacteria species were identified with the highest count for any one species being 500 CFU/in^ and a total sum of 1,600 CFU/in<

Mold

Interpretation of these results cannot be completed using standard practices. The standard practice for determining if an indoor environment is being impacted by mold is to compare the species and concentration of indoor mold samples to outdoor mold samples that were collected during the same sampling event, however, based on the data received it appears that there were no outdoor samples collected for comparison. Using an approach that is less desired than the standard practice, the following conclusions can be drawn from the data. Although there are no specific standards, the general rule of thumb for interpreting mold data usually considers concentrations greater than 10,000 CFU/in^ to be the low end of the spectrum for beginning additional mold investigation, and concentrations greater than 100,000 to signify “mold contamination”. The concentrations for each individual species, as well as the total sum for all species was well below 10,000 CFU/in^ In addition, the fungi species observed are the most frequent species identified and are ubiquitous in the environment, both outdoors and indoors. This leads to an overall conclusion that the concentration and species of mold present are typical of an indoor environment. In general, mold contamination is identified by finding visible mold growth that covers an area greater than 1 square meter. More information can be obtained from the American Industrial Hygiene Association at http://www.aiha.org/GovemmentAffairs-PR/html/oomold.htm .

Bacteria

The interpretation of the bacteria results has the same limitations as discussed above for mold, namely that indoor concentrations should be compared to outdoor concentrations. There is less information about indoor concentrations of bacteria than there is for mold, however one report http://www.atsdr.cdc.gov/HAC/PHA/frapklinfungi/ief pl .html from the Agency for Toxic Substances and Disease Registry (ATSDR) reports that concentrations of Bacillus at 1,000 CFU/in2 and Staphylococcus at 2,400 CFU/in2 are low and most likely are a normal part of the bacterial load. The concentration.s reported from 114 Liberty are much lower than these values. Therefore, even though there was not an appropriate outdoor sample collected for comparison, it can be concluded that the bacterial concentrations reported from the one indoor sample that was collected are typical of an indoor environment.

CITY_DEP_WORBY_CANNATA_SUBP_000018944

NYC-WTC_000363058

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363058Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →