horsepower electric leaf blower) shall be used to direct exhaust air against walls, ceilings, floors and other surfaces. When directing the exhaust, caution shall be taken to minimize disturbance and potential damage to furnishings and personal, belongings. ii. For modified aggressive air sampling forced air equipment shall not be employed. iii. All other procedures are identical for aggressive and modified aggressive air sampling. b. One 20-inch fan shall be installed per 10,000 cubic feet of room space and run at low speed. The fan shall operate continuously throughout sampling and shall not be turn ed off until sampling is completed. c. For studio apartments 3 samples shall be collected. For 1-bedroom apartments and above 5 samples shall be collected. Sampling equipment shall be placed in living areas and away from obstructions. The sampling cassette must be placed on a tripod and not taped to existing surfaces. d. Common spaces will be sampled using modified aggresive techniques (20 inch fans). For small spaces, less than 260 linear feet and 160 square feet, 3 samples will be collected. For large spaces greater than 260 linear feet or 160 square feet and less than 25,000 square feet 5 samplers will be collected. For spaces greater than 25,000 square feet, 1 sample will be collected for each 5,000 square feet. Sampling equipment shall be placed away from obstructions. The sampling cassette must be placed on a tripod and not taped to existing surfaces. e. Asbestos air samples shall be collected in accordance with the procedures specified in NIOSH Method 7400. Air sampling pumps will be operated at 10 liters per minute for eight (8) hours to achieve. To achieve minimum volume requirement of 4800 liters. f. Samples must be labeled and accompanied with completed chain of custody forms before shipping to the designated laboratory. The label must include the EPA Project Tracking Number. Samples will be packed, sealed and shipped to USEPA Contract Laboratory for analysis. g- All information must be maintained using the secure EPA website(url, user name and password to be provided by EPA). Dates for monitoring and/or cleaning shall be provided to EPA electronically in an EPA approved format within 24 hours. Information on sampling activities (date, sample ID) will be provided to EPA, via the website, within 24 hours of completion of analysis.
20. Pre-cleaning and Post-cleaning Wipe Sampling Procedures
a. The Project Monitor will collect pre and post-cleanup wipe samples at 5 percent of the residences cleaned up to a maximum of 50 units per quadrant. This sampling will consist of the collection of 3 pre clean-up and 3 post clean-up wipe samples for total metals and mercury (Note; a separate wipe sample is require for analysis for mercury). All wipe samples will be collected in accordance with procedures
5
CITY_21MC100_000439060 NYC-WTC_000363046
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000363028
USEPA/DEP roles for the WTC cleanup program and safety oversight.
11 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362970
Scope for DEP/contractor cleaning and sampling for WTC-related residences.
11 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000209480
Draft document detailing the scope of work for a residential dust cleaning program initiated by the EPA and DEP in July 2002.
10 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362992
Laboratory text outlining compliance with EPA/OSHA/NYSDOL regulations for cleaning and sampling related to WTC debris.
10 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000363017
Site inspections, surveys, and coordination for dust/debris cleanup.
11 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140330
Details project scope for scheduling, coordinating, and monitoring dust and debris cleanup with air sampling from apartments affected by World Trade Center collapse.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140337
Details project scope for scheduling, coordinating, and monitoring dust and debris cleanup with air sampling from apartments affected by World Trade Center collapse.
13 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139460
Emails forwarding latest drafts of cleaning and air monitoring scopes of work for review and comment.
13 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140385
Specific instructions for collecting bulk dust samples, labeling containers, and repairing insulation disturbed during sampling activities.
11 shared non-person entities · 1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140430
Draft contract detailing EPA and DEP collaboration on residential dust sampling and cleaning services for residents south of Canal Street.
10 shared non-person entities · 1 shared topics · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138725
EPA transmits revised scopes of work for WTC indoor cleaning and monitoring contracts to DEP.
13 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139482
Forwarded revised scopes of work for cleaning and monitoring contracts related to WTC indoor air quality.
12 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000161167
Forwarded draft Statements of Work for cleaning and monitoring activities requiring review by noon.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140330
Details project scope for scheduling, coordinating, and monitoring dust and debris cleanup with air sampling from apartments affected by World Trade Center collapse.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138743
EPA circulates latest draft scopes of work for WTC indoor dust cleaning program requesting comments.
Similarity score 0.986 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162352
EPA request for review and feedback on draft scope of work documents for WTC cleaning and air monitoring contractors.
Similarity score 0.986 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000139460
Emails forwarding latest drafts of cleaning and air monitoring scopes of work for review and comment.
Similarity score 0.986 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138659
Circulation of latest draft cleaning and monitoring statement of works for WTC for review and comment.
Similarity score 0.986 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000140330
Details project scope for scheduling, coordinating, and monitoring dust and debris cleanup with air sampling from apartments affected by World Trade Center collapse.
Similar indexed content
NYC-WTC_000363028
USEPA/DEP roles for the WTC cleanup program and safety oversight.
Similar indexed content
NYC-WTC_000140337
Details project scope for scheduling, coordinating, and monitoring dust and debris cleanup with air sampling from apartments affected by World Trade Center collapse.
Similar indexed content
NYC-WTC_000139460
Emails forwarding latest drafts of cleaning and air monitoring scopes of work for review and comment.
Similar indexed content
NYC-WTC_000140385
Specific instructions for collecting bulk dust samples, labeling containers, and repairing insulation disturbed during sampling activities.