NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos dust memo, May 29, 2002

Machine-extracted title · confidence 48%

memo discussing asbestos dust sampling methods and industry debate.

NYC-WTC_000362801
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

To: Commissioner Ward

From: Bob Avaltroni Department of Environmental Date: May 29, 2002 Protection 591 7 Ijnction Boulevard Subject: Asbestos Dust Sampling Flushing, New York 1 1373-5108

Asbestos dust sampling using microvaci has been an issue of debate among industry experts and scientists for over a Christopher O. Ward decade. The major issues for acceptance have been the lack of precision and Commissioner the variability of results based on sampling collection methods and types of surfaces sampled.

Robert C. Avaltroni On September 14, 2001, and subsequently on September 26, 2001, the Deputy Commissioner Department released a memorandum to building owners indicating “Wipe sampling and/or microvacuum sampling are not recognized methods for Bureau of Environmental asbestos sampling and should not be used”. This position was taken early in Compliance the response action by the Asbestos Control Program in recognition of the controversial aspects of the sampling and the lack of standards for determination of contamination and cleanliness.

In 1995, the American Society for Testing and Materials (ASTM) issued a standard test method for microvacuum sampling for asbestos.

1. This method placed the burden on the user to determine the applicability of regulatory limitations prior to its use. 2. The standard test method specifically stated the collection efficiency was unknown and varied among substrates. The properties that influence collection efficiency included surface texture, adhesion, particle size distribution, etc. 3. The method specifically stated to “not sample any debris or dust particles greater than 1mm in diameter”. This is due to the interference generated from particles greater than Immcand is a significant drawback for sample collection. 4. The test method therefore required the collection of multiple independent samples from the same area. Quality control for analysis was based on reanalysis of the same samples due to difficulty in preparing quantitative asbestos samples.

The test method did not describe procedures or techniques required to evaluate the safety or habitability of buildings and did not set a standard or guidance for *,***«*^. interpretation of the results. This method has not been adopted by any State or local regulatory agency.

; wiww.nyc.gov/'. e i

CITY_21MC100_002840827

NYC-WTC_000362801

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000362801Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →