SSSSSSSSISSB

Building Method or Number Sample Type Location Quartz Cristobalite Tridymite Calcite Portlandite Gypsum Mica Halite Settled surface dust 33 <%) Outdoor NS NS NS NS NS NS NS NS Settled surface dust 33 W Residence 1 NS NS NS NS NS NS NS NS Settled surface dust 33 w Residence 2 1 J ND ND ND 0 08 J 2 J ND ND

34 Air (pg/m") PM100 ND ND ASN ND ND ND ND ND

34 Air (pg/m’l PM10 ND ND ASN ND ND ND ND ND

34 Air (pg/m’) PM4 ND ND ASN ND ND ND ND ND

34 Air (pg/m1 PM2.5 ND ND ASN ND ND ND ND ND Settled surface dust 34 Common area ND ND ND ND ND ND ND ND Settled surface dust 34 (%)_______ Outdoor NS NS NS NS NS NS NS NS Settled surface dust 34 (%) Residence 1 NS NS NS NS NS NS NS NS Settled surface dust 34 (%) Residence 2 ND ND ND ND ND 3J ND ND

ASN: Analytical sensitivity not available. Mineral was not detected at any measured location using the associated method, analytical sensitivity is not known. Detect: Mineral was detected above the analytical sensitivity in at least one of the measured locations of the building using the associated method. J: Estimated value. Due to inconsistencies during sample collection/analysis, the result is only an estimate of the actual value. The actual value could be higher or lower than the value shown. ND: Not detected. Mineral was not detected at any measured location using the associated method. NS: Not sampled. The associated method was not used at any of the measured locations in the building. R: Result was rejected. Due to inconsistencies during sample collection/analysis, the result values for the sample were rejected. )4g/m^: microgram per cubic meter of air.

114

CITY_21MC100_002352395

NYC-WTC_000362163

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000362163Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000301668

Final report on airborne and [name] dust exposures in Lower Manhattan related to WTC events.

Similar indexed content

NYC-WTC_000276826

Final investigation report on airborne exposures to dust at World Trade Center recovery site.

Similar indexed content

Compare copies and versions →