Airborne asbestos TEM analysis, 9/2001

Machine-extracted title · confidence 42%

TEM asbestos analysis results for Warren & [name], DDC/PS 89 project,Sept 2001.

NYC-WTC_000361674–000361678
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY CLIENT: Warren & Panzer Engineers, P.C. PROJECT: DDC/PS 89 LABORATORY ID #: TOl-09-010 DATE OF REPORT: 09/25/01 ATHENICA ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS; 09/19/01 EfA/iAONMENTAL SERVICES INC. FILTER TYPE: M C E. EFFECTIVE FILTER AREA (mm"): 385 T«L 7M-745W Fax. (71S) 78^-4085 AVERAGE G.O. AREA 0.01003 a I LABORATORY RESULTS CLIENT LAB. ID LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. (It) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (strucL/cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (inn?) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./mm^) 0.5£S<S|iin S>5.0(im 26 TOl-09- West Cafeteria 1460 6 0.0602 0.0044 <0.0044 <16.62 NA~ NA~ NA NA 010-1543 27 TOl-09- North East 1465 6 0.0602 0.0044 <0.0044 <16.62 NA NA NA NA 010-1544 Cafeteria 1- 28 TO 1-09- South west 1475 6 0.0602 0.0043 <0.0043 <16.62 NA NA NA NA 010-1545 Cafeteria 29 T01-09-. Outside Elevator 1465 6 0.0602 0.0044 <0.0044 <16.62 NA NA NA NA 010-1546 1“ Floor- 30 TO 1-09- 1’‘ Floor 1475 6 0.0602 0.0043 <0.0043 <16.62 NA NA NA NA 010-1547 Stairwell

ANALYST LABORATORY DIRECTOR

LABORATORY CERTIFICATION NUMBERS; NVLAP 101958, ELAP 10955 o .Athenica Environmmtal Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. A Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis. If AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is N) supplied solely for the convenience of the client. I The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. Test reports may not be reproduced except in lull and with prior approval of AES Inc. The liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount ofthe invoice.

5

co co o o

NYC-WTC_000361678

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000361678Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →