AIRBORNE ASBESTOS ANALYSTS BY TRANSMISSION ELECTRON MICROSCOPY CLIENT: Warren & Panzer Engineers, P.C. PROJECT: DDC/PS 89 LABORATORY ID #; TOl-09-010 DATE OF REPORT: 09/25/01 ATHENICA ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 09/19/01 ENVIRONMENTAk SERVICES INC. FILTER TYPE: M.C.E. EFFECTIVE FILTER AREA (mn?): 385 Tai. (718) 78a-7n8O AVERAGE G.O. AREA (ninr): 0.01003 Fax. (718) 7»t-tOS5

LABORATORY RESULTS

CLIENT LAB. ID LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. •# (It) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (stnict/cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm’) (struc./cm^ CONC. STRUCT. STRUCT. SPECIFY (str./mm^) 0.55S<5|un S>5.0)un 11 TO 1-09- 4“* Floor 1480 6 0.0602 0.0043 <0.0043 <16.62 NA NA NA NA 010-1528 Hallway 12 TO 1-09- 4'*'Floor 1500 6 0.0602 0.0043 0.0043 16.62 0.0043 <0.0043 Chiys. NA 010-1529 Bathroom 13 TOl-09- 4“ Floor 1495 6 0.0602 0.0043 <0.0043 <16.62 NA NA NA ' NA 010-1530 Stairwell 14 TOl-09- 4“ Floor outside 1475 6 0.0602 0.0043 <0.0043 <16.62 NA NA NA NA 010-1531 Elevator 15 TOI-09- 4“ Floor 1470 6 0.0602 0.0044 <0.0044 <16.62 NA NA NA NA 010-1532 Classroom

ANALYST LABORATORY DIRECTOR

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955

.Mheniea Environmental Services Ine. (AES), is responsible only for information pertaining to samples taken by its employees. Air sampling cassettes will be stored for sixty (60) days. AES Inc., should be notified within this time frame for a true duplicate analysis. I If .AES Inc., did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is supplied solely for the convenience of the client. I The report relates only to items tested. This report must not be used to claim product endorsement by N VL.AP or any other agency of the U.S. Government. Test reports may not be reproduced except in frill and with prior approval of AES Inc. The liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice. I o 2

NYC-WTC_000361675

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000361675Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →