NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 13 pages

Final Air Monitoring and Bulk Sampling Report, PS 89M, Oct

Machine-extracted title · confidence 40%

Final air monitoring and bulk sampling report for PS 89M area, Oct 2001.

NYC-WTC_000361661–000361673
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

0^ Final Report of Air Monitoring and Bulk Sampling Services 4.1 Sample Collection

Air samples are collected by pulling air through a mixed cellulose ester filter (MCE), 25 millimeters (mm) in diameter, with a pore size of 0.45 micrometers for TEM analysis. A 120-volt AC powered, constant flow vacuum pump pulls the air at flow rates of 5 to 15 liters per minute. The pumps are calibrated prior to sampling, using a secondary calibration standard (rotometer). The secondary calibration standards are calibrated periodically (at least once every four months) using a primary standard (one liter bubble burette). The flow rate of each pump is rechecked following each sampling period.

4.2 Sample Analysis and Reporting

Transmission Electron Microscopy (TEM) analysis was performed by a New York State ELAP/NVLAP approved laboratory. All samples were analyzed by the TEM method in appendix A of Subpart E of 40 CFR 763. Asbestos structure concentrations are calculated by determining the number of structures coimted within an area of the filter. The result is an expression of the concentration of asbestos structure per square millimeter (s/mm^). TEM Clearance air monitoring results are considered satisfactory when the asbestos concentration of each individual samples is less than 70 s/mm\

4.3 Quality Control

Laboratory technicians involved in PCM air sample analysis have completed the NIOSH 582 Sampling and Evaluating Airborne Asbestos Debris course, or an equivalent. Technicians also participate in the NIOSH/AIHA (American Industrial Hygiene Association) Proficiency Analytical Testing (PAT) Program to ensure consistency in methodology. The laboratory maintains an in-house quality control (QC) program for PCM air samples whereby ten percent of all submitted samples are reanalyzed and documented in a QC manual. The laboratory also participates in a quarterly round robin QC program with several accredited laboratories throughout the United States.

4.4 Sample Results

Initial air monitoring indicated asbestos structure concentrations above 70 structures per millimeter square in Room 502 of the 5* Floor. Subsequent ambient air monitoring analysis results from samples taken in Room 502 indicated that the concentrations of airborne fibers within this room were less than 70 structures per millimeter square, the concentration set forth by EPA AHERA Regulations for re-occupancy of an area.

DDC Project No.: WTCEMERGE Warren & Panzer Engineers Project No. 1017.17.01 A Member of PS 89M, 201 Warren Street, Manhattan, New York The Warren & Pander ^002

CITY_21MC100_007143285

NYC-WTC_000361664

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000361664Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000230980

Application submitted to the DEP regarding cleaning procedures for a residential condominium, including exterior facade and interior duct work.

Similar indexed content

Compare copies and versions →