Test Sample Review: Air Sample Record Chain of Custody

Machine-extracted title · confidence 43%

Review of irregularities on Air Sample Record & Chain of Custody forms, 2001.

NYC-WTC_000360862–000360863
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

z PT&L Environmental Services z o Test Sample Review: "Air Sample Record Chain of Custody" Forms ■<

o i 1^ Example Laboratory Date Sample Number _________________ Irregularities on "Air Sample Record & Chain of Custody" ______________ co

o 1 Omega Labatories, Inc 10/23/2001 1212-1215 Date written over (10/23/01), 5 minutes between set ups (1) _________ _______________________ ■D o c o No technician signatures on transfer, did not check off weather conditions, no pump number,duplicafe CT Ca3 O> 2 Omega Labatories, Inc 10/25/2001 1306-1309 testing (see below sample numbers 1306-1309)____________________________________________ o' O oo 3 Omega Labatories, Inc 10/25/2001 1306-1309 Duplicate testing of these samples-see Omega Lab Report sample, no pump number_________________ ■D O) o ro No transfer signatures transferring samples to laboratory, no time off on sample number 56458, no 3. 03 4 Omega Labatories, Inc 10/14/2001 56456-56459 Omega Lab Analysis Report_______ No transfer signatures transferring samples to laboratory, no Omega Lab Analysis Report no weather o o o 5 Omega Labatories, Inc 10/14/2001 56464-56467 condition____________________________________________________________________________ c No transfer signatures transferring samples to laboratory, no Omega Lab Analysis Report, calculation error 3 CD 6 Omega Labatories, Inc 10/14/2001 56468-56471 on total volume on sample number 56471 (should be 990), no weather condition_____________________ No technician signatures, time off all same , lab name different from lab used to analyze samples, 7 Omega Labatories, Inc 9/28/2001 56029-56033 turnaround time does not conform to request on form__________________________________________ Time in/out very close for one technician, turnaround time does not conform to request on form, lab name 8 Omega Labatories, Inc 9/28/2001 56054-56058 on form different from lab used to analyze samples____________________________________________ No technician signature on transfer, no pump number, time in/out very close for one technician, lab name 9 Omega Labatories, Inc 9/29/2001 56081-56085 different from lab used to analyze samples__________________________________________________ No technician signature on transfer, total number of samples wrong , turnaround time does not conform to 10 Omega Labatories, Inc 9/29/2001 56095-56099 request on form, lab name different from lab used to analyze samples_____________________ No technician signature on transfer, turnaround time does not conform to request on form, lab name 11 Omega Labatories, Inc 9/29/2001 56100-56103 different from one used to analyze samples_________________________________________________ No technician signature on transfer, total number of samples wrong , turnaround time does not conform to request on form, times in/out very close for one technician, lab name different from lab used to analyze 12 Omega Labatories, Inc 9/30/2001 56122-56126 samples____________________ No technician signature on transfer, lab name different from lab used to analyze samples, total number samples wrong , turnaround time does not conform to request on form, time in/out very close for one 13 Omega Labatories, Inc 9/30/2001 56127-56131 technician,___________________________________________________________________________ Turnaround time does not conform to request on form, times in/out very close for one technician, lab name 14 Omega Labatories, Inc 9/30/2001 56153-56157 is different from lab used to analyze samples No pump number, turnaround time does not conform to request form, lab name is different from lab used 15 Omega Labatories, Inc 9/30/2001 56158-56162 to analyze samples____________________________________________________________________ No technician signature on transfer, turnaround time does not conform to request on form, lab name 16 Omega Labatories, Inc 9/21/2001 [iwa1-0008 different from lab used to analyze samples

No technician name or signature on transfer, turnaround time does conform to request on form, lab name 17 Omega Labatories, Inc 9/21/2001 0023-0030 different from lab used to analyze samples, no weather conditions noted, all flow readings are same No chain of custody form attached to Omega lab Analysis Report, turnaround time is 6 days 144 hours- 18 Omega Labatories, Inc 9/22/2001 129318-129325 appears long (2) No technician signature on transfer, flow reading all the same, turnaround time is much longer than I I» Omega Lab^orics, !nx 9/22/2001 0039-0046 request on form, lab name different from lab used to analyze samples. No technician signature on transfer, turnaround time is longer than request on form, lab name different ii 20 Omega Labatories, Inc 9/23/2001 0047-0054 from lab used to analyze samples^^_____________________________________________________ No technician signature on transfer, flow reading all the same, turnaround time is much longer than ! 21 Omega Labatories, Inc 9/23/2001 0053A-0060 request on form, lab name different from lab used to analyze samples, all the time out are the same No technician signature on transfer, turnaround time is longer than request on form, lab name different 22 Omega Labatories, Inc 9/24/2001 0061-0068 from lab used to analyze samples. CaJ ! CO fiotnirk 2 3/16/03

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000360862Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000339685

Review of irregularities on Air Sample Record & Chain of Custody forms from PT&L.

Similar indexed content

NYC-WTC_000281343

Review of air sample records and irregularities in chain-of-custody forms, 2001.

Similar indexed content

Compare copies and versions →