OSHA sampling results, asbestos, NYC site, Mar 2002

Machine-extracted title · confidence 42%

OSHA asbestos and noise sampling results; evaluation of fiber levels and exposure near rubble pile in financial district.

NYC-WTC_000360672–000360675
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

.Ud/U4/U2 13:15 EAA 212 337 2371 ■ ' ' USDUL USHA 1^004

around the perimeter are lower than those found directly over tire pile. To date, only one sample taken on the rubble pile showed dioxin levels which • exceeded background levels. Dioxins are considered collectively as suspect human carcinogens. OSHA does not have a PEL for dioxins. Polynuclear Aromatic Hydrocarbons OSHA has taken 110 samples (excluding blanks). The majority of the samples have not shown the presence of ben2o(a)pyrene and/or one or more of five additional fused polycyclic hydrocarbons; anthracene, acridine, pyrene, chrysene and phenanthrene. Sample results to date have identified eight samples which reached or exceeded OSHA’s coal tar pitch volatile PEL of 0.2mg/m’. These personal samples were taken on the pile on iron workers and grappler operators. OSHA continues to recommend the use of respiratory protection when working in tire debris field. Freon R-22, Hydrogen Fluoride & Phosgene: OSHAhas taken a total of 208 samples for Freon R-22 (chlorodiflouromethane), hydrogen fluoride, and phosgene. Only one Freon sample resulted in a detectable level of 6.4 ppm during the transfer of Freon from the auxiliary chiller, and all other samples were none-detected. OSHA does not have an exposure limit for Freon R-22. (The NIOSH REL for Freon is lOOOppm..) Sampling for tlie decomposition products of Freon R-22, hydrofluoric acid (HF) and phosgene showed no detectable levels.

Inorganic Acids OSHA has taken approximately 129 samples for inorganic acids such as hydrochloric, phosphoric, and sulfuric acids. Three samples for sulfuric acid were found to exceed OSHA’s permissible exposure limit (PEL) of 1 mg/m\ Workers were sorting debris. Oxides of Nitrogen/ Sulfur: Sampling on grappler operators on the rubble pile, and on employees at the truck wash stations revealed trace levels of nitric oxide and nitrogen dioxide. SO2 personal and area results were found to be below OSHA limits-

Page 3 of 4

CITY_21MC100_002843816

NYC-WTC_000360674

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000360674Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

OSHA sampling summary, 3/4/02

NYC-WTC_000339820

OSHA sampling results: asbestos and noise data for rubble pile workers as of 3/4/02.

Similar indexed content

OSHA sampling summary, 4/23/02

NYC-WTC_000339777

OSHA sampling results: asbestos and noise data for debris-field operations as of 4/23/02.

Similar indexed content

Compare copies and versions →