Page image not rendered yet. The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
I
elevated levels.
Dioxins: The single sample taken by OSHA and analyzed by the EPA, representing
exposure on the pile, showed elevated levels of dioxins. These levels were
substantially higher than background levels but comparable to levels found by the
EPA on the rubble pile. The dioxins found here are emitted from the on-going
rubble fire, OSHA does not have a worker standard for dioxins. Dioxins are
considered collectively as suspect human carcinogens. Some of the individual
compounds are considered to be known human carcinogens. OSHA has taken
seven additional samples which have been forwarded for analysis. OSHA is
currently conducting additional sampling for dioxins and is coordinating with EPA,
and Salt Lake City Analytical Laboratory to more fully characterize exposure and
risk around the rubble pile.
Polynucleated Aromatic
Hydrocarbons: OSHA identified several elevated samples, three of which reached or
exceeded OSHA’s coal tar pitch volatiles PEL of .2mg/M’ These personal
s
samples were taken on the pile on iron workers and grappler operators.
OSHA continues to strongly recommend the use of respiratory protection
when working on the rubble pile.
Pending Analysis: In response to information about exposure to the combustion by-products of Freon
22 used in the air conditioning systems of WTC towers, OSHA conducted
sampling for fluorides as HF. Results are pending.
J
i
I
Page 2 of 2
CITY_21MC1OO_OO925O67O
NYC-WTC_000357927
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000357927Source: NYC Law Department, mirrored locally