NYC 9/11 Public Portal Document
liberty
Mutual.
Industrial Hygiene Measurements
Summary for Week of 04/05/02 to 04/12/02
Some of the columns in the attached summaiy may require explanation:
Analyte Class - This column includes general category of the agents (substances) which were sampled.
# of Samples - This indicates how many individual samples were collected for the agent class listed.
# of Analysi.s - This i.s the number of individual analyses performed. If only one analysis is performed on each
sample, then the number of analytes wiU equal the number of samples. However, most samples are analyzed for
more than one agent as follows:
Metals: Aluminum, antimony, arsenic, barium, bcryUium, cadmium, calcium, chromium, cobalt, copper,
iron, lead, magnesium, manganese, nickel, selenium, silver, thallium, tin, titanium, vanadium, and zinc.
Metal samples are sometimes also analyzed for total particulate.
Silica: Respirable dust, quartz, and cristobalite.
Acids: Hydrobromic acid, hydrochloric acid, hydrofluoric acid, nitric add, phosphoric add and sulfuric
acid
il Sulfides: Hydrogen sulfide and sulfur dioxide
OEL - Occupational Exposure Limit is the lower of the OSIIA PEL or ACGIH TLV. PELs are established by
an OSHA rule-making process and are the legal occupational exposure standards. TLVs are voluntary
guidelines for occupational exposure which are established by the American Conference of Governmental
Industrial Hygienists, a private professional organization.
Highest % OEL - This is tlie percentage of the occupational exposure limit (OEL) that the highest result
represents. This is the value in the “Highest Result” column divided by the lower of either the PEL or TLV and
converted to a percentage.
Shift Adjusted OEL - The OEL reduced to compensate for the reduced recovery time and longer exposure
11
time posed by a 7 day per week , 12 hour shift work schedule.
Highest % of Shift Adjusted OEL - This is the percentage of shift adjusted OEL that the highest result
represents.
#of NQs - This is the number of analyses that reported that concentration as “not quantifiable” (NQ).
% of NQ - This is the percent of the total analyses which were reported as “not quantifiable”.
CITY_21MC100_011914234
NYC-WTC_000357613
OCR can misread numbers and units. Confirm readings against the page image before using them.