NYC 9/11 Public Portal Document
JLC ENVIRONMENTAL CONSULTANTS, INC.
200 ParkAvenue South, Suite 1001, New York, NewYork 10003
Phone: (212)420-8119 Fax: (212) 420-6092
Project No.: 01-2102
Metcalf & Eddy Inc. ELAP Lab Code: 11029
Analyte: ASBESTOS
3 Werner Way. Suite 310 NIOSH and AIHA Lab Code: 100273
Date Received: 9/29/01
Lebanon, NJ 08833 NVLAP Lab Code: 101953
Date Analyzed: 9/29/01
SUMMARY OF ANALYTICAL RESULTS - PLM Batch ft: 0109B386
Site: 3 World Financial Center - Floors 3-26
SAMPLE #
ASBESTOS TOTAL % OF rnM<iTiTi
DATE DESCRIPTION / L OCA TION COLOR DETECTED? ASBESTOS CONSTITUENTS
COLLECTED
LAB»
CLIENT S SAMPLE ft
25001 25th Floor/ Sample From Area of Damage BEIGE NO 0%' CELL 8%
at South East Corner of Building/ Sample NFIB 92%
9/27/01
11137 of Debris
25-001
25002 25th Floor/ Sample From Area of Damage BROWN NO 0% CELL 25%
9/27/01 at South East Corner of Building/ Sample NFIB 75%
11138 of Debris
25-002
25003 25th Floor/ Sample From Area of Damage BEIGE NO 0% CELL 20%
9/27/01 at South East Corner of Building/ Sample NFIB 80%
11139 of Debris
25-003
25004 25th Floor/ Sample From Area of Damage BROWN NO 0% CELL 15%
9/27/01 at South East Corner of Building/ Sample FBGL 15%
NFIB 70%
11140 of Debris
25-004
‘INSUFFICIENT MATERIAL SUBMITTED **TEM RECOMMENDED ***NOT ANALYZED POSITIVE STOP
ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Sample Analysis by:
Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chrysotile Asbestos PAPF = Paper Fiber
AMOS = Amosite Asbestos MINVV = Mineral Wool
CROC = Crocidolite Asbestos FBGL = Fiberglass
Method of Sample Preparation and Analysis: ACTN = Actinolite Asbestos SYNF = Synthetic Fibers
All samples wzere prepared and analyzed in accordance with the EPA TREM = Tremolite Asbestos CELL = Cellulose
"Method for the Determination of Asbestos in Bulk Building Materials" ANTH = Anthophylite Asbestos NFIB = Non-Fibrous
USEPA/ 600/ R-93/116. July 1993. ORGM = Organic Material
WOLL = Wollastonite
Instrumentation: HSHR = Horse Hair
OTHR = Other
Olympus PLM, Model BH-2A/M Slereomicroscope, Model
VMZ 1x-4x. Gulam Machhiwala
Laboratory Director
.. Analytical results reflect the make up of the materials only in the areas sampled. This "Summary of Analytical Results" shall not be reproduced except in full, without the wrilte
approval of JLC Laboratory, and it must not be used by client to claim product endorsementby NVLAP or any agency of the U.S. Government. This method is not applicable to
samples containing large amounts of fine fibers below the resolution of the light microscope. The value of this method is limited to the quantitative identification of asbestos
and the semi-quantitative determination of asbestos content of bulk samples, expressed as a percentage of the protected area. Quantitation of asbestos content was’
determined with a visual volume estimate, a calibrated visual area estimate, and/or point counting procedure. CAUTION: Other fibers with optical properties similar to asbesto
may give positive interferences and will be considered asbestos under this methodology. Also, PLM is not consistently reliable in detecting asbestos in floor coverings and
similar non-ftiable organically-bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can b
considered or treated as non-asbeslos containing.
Page 1 of 3
CITY_21MC100_011914222
NYC-WTC_000357522
OCR can misread numbers and units. Confirm readings against the page image before using them.