JLC ENVIRONMENTAL CONSULTANTS. INC.
200 Park Avenue South, Suite 1001, New York, New York 10003
Phone: (212) 420-8119 Fax: (212) 420-6092
Project No.: 01-2102
Metcalf & Eddy Inc. ELAP Lab Code: 11029
Analyte: ASBESTOS
3 Werner Way, Suite 310 NIOSH and AIHA Lab Code: 100273
Date Received: 9/29/01
Lebanon, NJ 08833 NVLAP Lab Code: 101953
Date Analyzed: 9/29/01
Batch #: 0109B386
SUMMARY OF ANALYTICAL RESULTS - PLM
Site: 3 World Financial Center - Floors 3-26
SAMPLE #
ASBESTOS TOTAL % OF r-nucTiTi ,PNT<i
DATE DESCRIPTION /LOCA TION COLOR DETECTED? ASBESTOS CONSTITUENTS
COLLECTED
LAB#
CLIENT'S SAMPLE #
22005 22nd Floor/ East Side Office Adjacent to BEIGE NO 0% CELL 10%
9/27/01 Severely Damaged South East Corner/ NFIB 90%
11131 Sample of Debris
22-005
22006 22nd Floor/ East Side Office Adjacent to GRAY NO 0% CELL 25%
Severely Damaged South East Corner/ FBGL 15%
9/27/01
NFIB 60%
11132 Sample of Debris
22-006
‘INSUFFICIENT MATERIAL SUBMITTED "TEM RECOMMENDED ”*NOT ANALYZED POSITIVE STOP
ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Sample Analysis by:
Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chrysotile Asbestos PAPF = Paper Fiber
AMOS = Amosite Asbestos MINW = Mineral Wool
CROC = Crocidolite Asbestos FBGL = Fiberglass
Method of Samrrle Preparation and Analysis:
ACTN = Actinolite Asbestos SYNF = Synthetic Fibers
All samples were prepared and analyzed in accordance with the EPA TREM = Tremolite Asbestos • CELL = Cellulose
"Method for the Determination of Asbestos in Bulk Building Materials" ANTH = Anttiophylite Asbestos NHB = Non-Rbrous
USEP/V 600/ R-93/116. July 1993. ORGM = Organic Material
WOLL = Wollastonite
Instrumentation: HSHR = Horse Hair
(>» OTHR = Other
Olympus PLM, Model BH-2/VM Stereomicroscope, Model
VMZ 1x-4x. Gulam Machhiwala
Laboratory Director
Analytical results reflect themake up of the materials only in the areas sampled. This "Summary of Analytical Results" shall not be reproduced except in full, without the writte
approval of JLC Laboratory, arid it riiust not be used by client to claim product endorsement by NVLAP or any agency of theU.S. Government. This method is not applicable to
samples containing large amounts of fine fibers below the resolution of the light microscope. The value of this mettrod is limited to the quantitative identification of asbestos
and the semi-quantitative determination of asbestos content of bulk samples, expressed as a percentage of the protected area. Quantitation of asbestos content was
' determined with a visual volume estimate, a calibrated visual area estimate, and/or point counting procedure. CAUTION; Other fibers with optical properties similar to asbesto
may give positive interferences and will be considered asbestos under this methodology. Also, PLM is not consistently reliable in detecting asbestos in floor coverings and
similar non-ftiable organically-bound materials. Quantitative transmission electron microscopy is currently the only method that t^n be used to determine if (his material can b
considered or treated as non-asbestos containing.