NYC 9/11 Public Portal Document
JLC ENVIRONMENTAL CONSULTANTS, INC.
200 Park Avenue South, Suite 1001, New York, New York 10003
Phone: (212) 420-8119 Fax: (212) 420-6092
Project No.: 01-2102
Metcalf & Eddy Inc. ELAP Lab Code: 11029
Analyte: ASBESTOS
3 Werner Way, Suite 310 NIOSH and AIHA Lab Code: 100273
Date Received: 9/28/01
Lebanon, NJ 08833 NVLAP Lab Code: 101953
Dale Analyzed: 9/29/01
SUMMARY OF ANALYTICAL RESULTS - PLM Batch #: 0109B385
Site: 3 World Financial Center- Floors 3-26
SAMPLE If
DATE ASBESTOS TOTAL % OF CONSTITUENTS
DESCRIPTION / LOCA TION COLOR DETECTED? ASBESTOS CONSTITUENTS
COLLECTED
LAB#
CLIENT'S SAMPLE #
14005 14th Floor/ South East/ Charles Reinhards/ WHITE/ NO 0% FBGL 20%
9/28/01 East Window/ Sample of Debris BROWN NFIB 80%
10961
14-005
14006 14th Floor/ South East/ Bruce Harting/ BROWN/ NO 0% NFIB 100%
9/28/01 Window/ Sample of Debris WHITE
10962
14-006
14007 14th Floor/ South East/ Bruce Harting/ GRAY NO 0% CELL 20%
9/28/01 Window/ Sample of Debris NFIB 80%
10963
14-007
14008 14th Floor/ South East/ Misa Abe's BROWN/ NO 0% CELL 10%
9/28/01 Cubicle/ Sample of Debris WHITE NFIB 90%
10964
14-008
•INSUFFICIENT MATERIAL SUBMITTED "TEM RECOMMENDED “•NOT ANALYZED POSITIVE STOP
Sample Analysis by: ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chrysotile Asbestos PAPF= Paper Fiber
AMOS = Amosite Asbestos MINW = Mineral Wool
CROC = Crocidolite Asbestos FBGL = Fiberglass
of Sample Preparation and Analysis:
ACTN = Actinolite Asbestos SYNF = Synthetic Fibers
All samples were prepared and analyzed in accordance with the EPA TREM = Tremolite Asbestos CELL = Cellulose
"Method for the Determination of Asbestos in Bulk Building Materials" ANTH = Anthophylite Asbestos NFIB = Non-Fibrous
USEPA/ 600/ R-93/116, July 1993. ORGM= Organic Material
WOLL = Wollastonite
Instrumentation: HSHR = Horse Hair
OTHR = Other
Olympus PLM, Model BH-2/VM Slereomicroscope, Model -4
VMZ 1x-4x. Gulam Machhiwala
Laboratory Director
Analytical results reflect the make up of the materials only in the areas sampled. This "Summary of Analytical Results" shall not be reproduced except in full, without the writle
approval o1 JLC Laboratory,- and it must not be used by client to claim product endorsement by NVIAP or any agency of the U.S. Government. This method is not applicable to
samples containing large amounts of fine fibers below the resolution of the light microscope. The value of this method is limited to the quantitative identification of asbestos
and the semi-quantitative determination of asbestos content of bulk samples, expressed as a percentage of the protected area.; Quantitation of asbestos content was
determined with a visual volume estimate, a calibrated visual area estimate, and/or point counting procedure. CAUTION: Other fibers with optical properties similar to asbesto
may give positive interferences and will be considered asbestos under this methodology. Also, PLM is not consistently reliable in delecting asbestos in floor coverings and
similar non-friable organically-bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can b
considered or treated as non-asbestos containing.