NYC-WTC_000356245
Form listing asbestos sampling details, vehicle samples and PLM results.
8 shared non-person entities · similarity 0.956
machine-extracted · confidence unavailable · Check page ↗Draft lab report listing asbestos results as not detected for multiple samples.
NYC-WTC_000356223–000356240OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
DRAFT New York State Department of Labor 6 of 18
Sample ID Agency Date SiteName or Address Sample Sample Analyte Quantifier Results Unit PESH Analysis Method Comments Sampled type duration PEL (min) 11502-7 PESH 1/15/02 Firehouse, Engine 10 wipe iron 75.1 ug NIOSH 7300 2nd floor, top of lockers PESH 1'15/Q^r 1 wipe lead 1.97 ug ■ NIOSH 7300 2nd floor, top of lockers 11502-7 Firehouse, Engine 10 11502-7 PESH 1/15/02 Firehouse, Engine 10 wipe magnesium 130 ug NIOSH 7300 2nd floor, top of lockers 11502-7 PESH 1/1^02 Firehouse, Engine 10 wipe manganese 1.7 ug NIOSH 7300 2nd floor, top of lookers 11502-7 PESH 1/15/02 Firehouse, Engine 10 wipe nickel 0.72 ug ■ NIOSH 7300 2nd floor, top of lockers 11502-7 PESH 1/15/02 Firehouse, Engine 10 wipe zinc 11.4 ug NIOSH 7300“ 2nd floor, top of lockers JI 502-8 PESH" 1/15/02 Firehouse, Engine 10 wipe asbestos not detected % PLM 2nd floor, radio table 11502-9 PESH 1/15/02 Firehouse, Engine 10 wipe asbestos not detected % 'PLM ___ _ 2nd floor, wall above a/c 11702-1 PESH 1/17/02 Vehicle, Engine 33 wipe asbestos not detected % PLM dashboard________________ 11702-10 PESH 1/17/02 Vehicle, Ladder 9 wipe asbestos not detected PLM dash 11702-11 PESH 1/17/02 Vehicle, Ladder s wipe aluminum 45.7 ug NIOSH 7300 R side floor, after vents on 11702-11 PESH 1/17/02 Vehicle, Ladder 9 wipe cadmium 0.476 ug “ NIOSH 7300 R side floor, after vents on 11702-11 PESH 1/17/02 Vehicle, Ladder 9 wipe cobalt not detected ug NIOSH 7300 R side floor, after vents on 11702-11 PESH 1/17/02 Vehicle, Ladder 9 wipe copper 6.21 ug ■ NIOSH 7300 R side floor, after vents on 11702-11 PESH 1/17/02 Vehicle, Ladder 9 wipe iron 578 ug nFoshtsoo R side floor, after vents on 11702-11 PESH 1/17/02 Vehicle, Ladder 9 wipe lead 9.1 ug NIOSH 7300 R side floor, after vents on 11702-11 PESH 1/17/02 Vehicle, Ladder 9 wipe magnesium 73.6 ug Kii6"SH 736"6"" R side floor, after vents on 11702-11 PESH 1/17/02 Vehicle, Ladder 9 wipe manganese 3.42 ug NIOSH 7300 R side floor, after vents on 11702-11 PESH 1/17/02 Vehicle, Ladder 9 wipe nickel 0.81 ug NIOSH730T R side floor, after vents on 11702-11 PESH 1/17/02 Vehicle, Ladder 9 wipe zinc 26.5 ug NIOSH 7300 R side floor, after vents on 11702-12 PESH 1/17/02 Vehicle, Ladder 9 wipe mercury not detected ug ~ NIOSH 6009 driver side floor, after vents on %‘
11702-13 PESH 1/17/02 Vehicle, Ladder 9 wipe asbestos not detected PLM rear cab console, after vents on 11702-14 PESH" 1/17/02 Vehicle, Ladder 9 wipe aluminum 10.9 ug NIOSH 7300 back seat after vents on 11702-14 PESH JI/17/02 Vehicle, Ladder 9 wipe cadmium 0.423 ug NIOSH 7300 back seat after vents on 11702-14 "PESH 1/17/02 Yehicle, Ladder 9 wipe cobalt not detected “ NIOSH 7300 back seat after vents on 11702-14 PESH 1/17/02 Vehicle, Ladder 9 wipe copper 2.39 ug NIOSH 7300 back seat after vents on 11702-14 PESH 1/17/02 Vehicle, Ladder 9 wipe iron 40.7 ug "NIOSH 7300 back seat after vents on 11702-14 PESH 1/17/02 Vehicle, Ladder 9 wipe lead 2,29 ug NIOSH 7300 back seat after vents on______ 11702-14 PESH 1/17/02 Vehicle, Ladder 9 wipe magnesium 16 NIOSH 7300 back seat after vents on 11702-14 PESH 1/17/02 Vehicle, Ladder 9 wipe manganese 0.44 ug " NIOSH 7300 back seat after vents on 11702-14 PESH 1/17/02 Vehicle, Ladder 9 wipe nickel 0.71 ug nioshYsoo"" back seat after vents on 11702-14 PESH 1/17/02 Vehicle, Ladder 9 wipe zinc 14.5 ug "NIOSH 7300 back seat after vents on______ 11702-15 PESH 1/17/02 Ladder 9 Firehouse wipe asbestos not detected "PLM floor below turnout gear Q PESH top of dash radio 11702-16 1/17/02 Vehicle, Ladder 7 wipe asbestos not detected PLM H 11702-17 PESH 1/17/02 Vehicle, Ladder 7 wipe aluminum 103 ug NIOSH 7300 top of clipboard l"^ 11702-17 PESH 1/17/02 Vehicle, Ladder 7 wipe cadmium not detected ug NIOSH 7300 top of clipboard to PESH j vciiiCic, LadutJl 7 COuait iiui ueteuicu I ( wv VI Vllf-rwaiM
S 11702-17 PESH 1/17/02 'vehicle, l^er 7 wipe copper 1.84 ug " NIOSH 7300 top of clipboard O 11702-17 PESH 1/17/02 iVehicle, Ladder 7 wipe iron 25.7'ug “NiOSH 7300 top of clipboard o PE^ 0.77'ug o 11702-17 1/17/02 jVehicle, Ladder 7 wipe lead " NIOSH 7300 top of clipboard I 11702-17 PESH 1/17/02 "lyehicle. Ladder 7 wipe magnesium 22.6 ug " NIOSH 7300 top of clipboard o 11702-17 PESH 1/17/02 I vehicle. Ladder 7 wipe manganese 0.43 ug NIOSH 7300 top of clipboard o 11702-17 PESH VI7/02 Vehicle, Ladder 7 wipe nickel 0.33 ug " NIOSH 7300 top of clipboard 11702-17 PESH 1/17/02 Vehicle, Ladder 7 wipe zinc 4.28 ug NIOSH 7300 top of clipboard Ui co 11702-18 PESH 1/17/02 Vehicle, Ladder 7 wipe mercury not detected ug NIOSH 6009 dashboard co 11702-19 ^SH 1/17/02 Vehicle, Ladder 7 wipe asbestos not detected % PLM blower near windshield, vent on <1702-2 PESH 1/17/02 Vehicle, Engine 33 wipe aluminum 32.2 ug NIOSH 7300 i middle console
NYC-WTC_000356228
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000356245
Form listing asbestos sampling details, vehicle samples and PLM results.
8 shared non-person entities · similarity 0.956
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000356241
Draft NYSDOL/PESH lab form showing cadmium and asbestos results with vehicle samples.
7 shared non-person entities · 1 shared topics · similarity 0.926
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000356243
PESH sampling results noting back seat and other locations for cadmium exposure.
7 shared non-person entities · 1 shared topics · similarity 0.923
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000322090
Draft lab-air sample results from FDNY tests on responders/areas at WTC.
5 shared non-person entities · similarity 0.914
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000356258
Lab analysis focusing on asbestos content and related metrics for wipe samples.
5 shared non-person entities · similarity 0.910
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000356221
Draft lab report with sampling data and PESH parameters for vehicle interior samples.
5 shared non-person entities · similarity 0.908
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000281865
NY State PESH mercury exposure samples for firefighters and police; not detected.
10 shared non-person entities · 1 shared topics · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138846
OSHA transmits NYS DOL data report containing sample summaries and worker information for WTC.
11 shared non-person entities · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138561
Data compilation containing World Trade Center worker and environmental information from state Department of Labor.
11 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000164145
Lab/Data correspondence regarding data attachments for WTC dataset.
10 shared non-person entities · 1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340910
Draft NYS Department of Labor air sampling form placeholder for occupational exposure data.
7 shared non-person entities · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000341064
Draft lab results for asbestos content at plaza site near Stuyvesant HS, Sept 2001.
11 shared non-person entities · similarity 0.910
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000281865
NY State PESH mercury exposure samples for firefighters and police; not detected.
Similarity score 0.983 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000281865
NY State PESH mercury exposure samples for firefighters and police; not detected.
Similarity score 0.981 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000281865
NY State PESH mercury exposure samples for firefighters and police; not detected.
Similarity score 0.978 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000281865
NY State PESH mercury exposure samples for firefighters and police; not detected.
Similarity score 0.978 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138561
Data compilation containing World Trade Center worker and environmental information from state Department of Labor.
Similarity score 0.977 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000281865
NY State PESH mercury exposure samples for firefighters and police; not detected.
Similarity score 0.977 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000281865
NY State PESH mercury exposure samples for firefighters and police; not detected.
Similar indexed content
NYC-WTC_000138846
OSHA transmits NYS DOL data report containing sample summaries and worker information for WTC.
Similar indexed content
NYC-WTC_000138561
Data compilation containing World Trade Center worker and environmental information from state Department of Labor.
Similar indexed content
NYC-WTC_000164145
Lab/Data correspondence regarding data attachments for WTC dataset.
Similar indexed content
NYC-WTC_000356245
Form listing asbestos sampling details, vehicle samples and PLM results.
Similar indexed content