REL for Freon is 1 OOOppm..) Sampling for the decomposition products of Freon R-22,
hydrofluoric acid (l^j^^S^osge^ Ih^wiS no detectabft 1^1
Inorganic Acids OSHA has taken approximately 79 samples for inorganic acids such as hydrochloric,
5 4-.i X^osghonc, and s^^iyjc^e^% "^wo sampl^fc^^ulfuric exoeed
OSHA’s permissible'exposure limit (PEL) of 1 mg^\ * *
Oxides of Nitrogen/
Sulfur: Sampling on grappler operators on the rubble ptle, and on empioyees’atithe truck wash
stations revealed trace levels of nitric oxide and nitrogen dioxide. This was repeated (1)
sample, now that the wash station is been enclosed. SO, personal and area results were
• found to be below O^^IA^irrj^t^^
* 4 Q ‘J .
Metals; OSHA has taken a tot^l^of^O^n^Hes (excluding bulk and blank samples) to monitor
worker exposures to dus8, fumes, ^des, and other compounds of metals such as
antimony, beryllium, chromium, cobalt, copper, iron, lead, manganese, mercury,
molybdenum, mck?!, vanj&iu^^ziy:, cadmiurrty-^a^esium, and arsenic, ^sufts from
these samples ar# g^erally well befow the applicable OSHA limits. However, torch
cutting and burning structural steel at the rubble pile have resulted in instances of
overexposures as follows: copper (12); iron oxide (23); lead (12); and cadmium (2).
Accordingly, OSHA is recommending that workers engaged in these operations wear
appropriate respiratory protection. See information below for the specific counts in
regards to mercury.
Mercury OSHA has taken 223 air samples for inorganic mercury. Results for 223 of those air
samples have been received and no mercury was detected. Also, 36 bulk samples
previously collected from rubble were re-analyzed for mercury and none was detected.
Additionally, 10 bulks were taken on 1/3, with one (1) sample detecting mercury at
0.9ppm and nine (9) samples being non-detected. 38 bulk samples were taken between
1/8 and 1/11/02; results indicate 0.1 to 0.2 ppm mostly in around the footprint of Bldg.-
6, in the pit between WTC tower 1&2.
Ionizing Radiation: A survey of the rubble pile was conducted on 10/22-10/23 to check for latent radiation
with particular attention to alpha radiation. Results show no elevated levels of concern
from either known building latent radiation sources or any tenorist origin source
materials.