NYC 9/11 Public Portal Document
Sulfur: Sampling on grappler operators on the rubble pile, and on employees manning
truck wash stations revealed trace levels of nitric oxide and nitrogen dioxide.
SO2 personal and area results were found to be below OSHA limits.
Metals: As of 11/13/01 OSHA has taken 429 air samples to monitor worker exposures
to dusts, fumes, oxides, and other compounds of metals such as antimony,
beryllium, chromium, cobalt, copper, iron, lead, manganese, molybdenum,
nickel, vanadium, zinc, cadmium, magnesium, arsenic, and mercury. Results
from these samples are generally well below the applicable OSHA limits.
However, torch cutting and burning structural steel at the rubble pile have
resulted in instances of overexposures as follows: copper (7); iron oxide (8);
lead (7); and cadmium (2). Accordingly, OSHA is recommending that workers
engaged in these operations wear appropriate respiratory protection.
Ionizing Radiation; A survey of the rubble pile was conducted on 10/22-10/23 to check for latent
radiation with particular attention to alpha radiation. Preliminary results show
no elevated levels.
Dioxins: OSHA has taken samples for dioxin and these samples were analyzed by EPA.
One initial sample, representing exposure directly on the pile, showed elevated
levels of dioxins when compared to ambient background levels. This value
was comparable to the levels found by EPA sampling. The dioxins at this
location are being emitted from the on-going rubble fire. Additional sampling
was conducted around the perimeter of the pile and revealed levels that were
considerably lower than those on the rubble pile. Dioxins are considered
collectively as suspect human carcinogens. OSHA has taken additional
samples which have all been forwarded for analysis. OSHA does not have a
worker standard for dioxins. OSHA is coordinating with EPA, and the Salt
Lake City Analytical Laboratory to fully assess the risk posed by the elevated
levels of dioxins.
Polynuclear
Aromatic
Hydrocarbons: OSHA has taken 56 samples. Sample results to date have identified several
elevated samples, four of which reached or exceeded OSHA’s coal tar pitch
volatile PEL of 0.2mg/m^' These personal samples were taken on the pile on
iron workers and grappler operators. OSHA continues to strongly recommend
the use of respiratory protection when working on the rubble pile.
Freon R-22,
Hydrogen Fluoride
& Phosgene: OSHA has taken 29 samples for Freon R-22 (chlorodiflouromethane). Sample
results received reveal non-detectable airborne levels. In response to
information about exposure to the decomposition by-products of Freon R-22
used in the air conditioning systems of WTC towers, sampling for hydrofluoric
acid (HF) had been conducted. Results for HF revealed non-detectable
levels. Sample results for phosgene show non-detectable levels.
Page 2 of 2
CITY_21MC100_008918503
NYC-WTC_000354272
OCR can misread numbers and units. Confirm readings against the page image before using them.