Sulfur: Sampling on grappler operators on the rubble pile, and on employees manning
truck wash stations revealed trace levels of nitric oxide and nitrogen dioxide,
SO, personal and area results were found to be below OSHA limits
Metals: As of 11/3/01 OSHA has taken 368 air samples to monitor worker exposures
to dusts, fumes, oxides, and other compounds of metals such as antimony,
beiyllium, chromium, cobalt, copper, iron, lead, manganese, molybdenum.
nickel, vanadium, zinc, cadmium, magnesium, arsenic, and mercury. Result.s
from these samples are generally well below the applicable OSH.A. limits.
However, torch cutting and burning structural steel at the rubble pile have
resulted in instances of overexposures as follows; copper (6 ); iron oxide (7);
lead (7); and cadmium (2). Accordingly, OSHA is recommending that workers
engaged in these operations wear appropriate respiratory protection.
Ionizing Radiation; A survey of the rubble pile was conducted on 10/22-10/23 to check for latent
radiation with particular attention to alpha radiation. Preliminary results show
no elevated levels.
Dioxins: The single sample taken by OSHA and analyzed by the EPA, representing
exposure on the pile, showed elevated levels of dioxins. These levels were
substantially higher than background levels but comparable to levels found by
the EPA on the rubble pile. The dioxins found here are emitted from the on
going rubble fire. OSHA does not have a worker standard for dioxins. Dioxins
are considered collectively as suspect human carcinogens. Some of the
individual compounds are considered to be known human carcinogens. OSHA
has taken additional samples which have all been forwarded for analysis.
OSHA is coordinating with EPA, and Salt Lake City Analytical Laboratory to
more fully characterize exposure and risk around the rubble pile.
Polynucleated
Aromatic
Hydrocarbons: OSHA identified several elevated samples, three of which reached or exceeded
OSHA’s coal tar pitch volatile PEL of .2mg m These personal samples were
taken on the pile on iron workers and grappler operators. OSHA continues to
strongly recommend the use of respiratory protection when working on the
rubble pile.
Freon R-22,
Hydrogen Fluoride
«& Phosgene: OSHA has conducted sampling for Freon R-22 (chlorodiflouromethane).
Sample results received reveal non-detectable airborne levels. In response to
information about exposure to the decomposition by-products of Freon R-22
used in the air conditioning systems of WTC towers, sampling for hydrofluoric
acid (HF) had been conducted. Results for HF revealed non-detectable
levels. Sample results for phosgene show non-detectable levels.