NYC-WTC_000318672
Asbestos micro-vacuum sampling report for Office Equipment area, 40 Worth Street/4th Floor, Jan 7, 2003.
11 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗Asbestos micro-vacuum sampling for NYC Mayor's Office of Operations; sites at Church and Worth Streets; TRC.
NYC-WTC_000354038–000354043OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
QJfieeEqiopmeinAs»KiosiaiarthviutaiM Soxipting Report January 7,2oa3 100 Church Sirttt Worth Strett, Yort. New York TRC Project Number 3S0S2-0000-00O15
Results for samples collected inside the equipment at 40 Worth Street were detected in following concentrations (in str/cm^):
• CPUs 7.97810 136,960 • Printers <2,12810 6,383 • Projector < 1,596 , • Scanner 4,787 • Monitor 136,960 • Laptop 19,547 computer • Copier 51,061 • Fax 3,191 machine The geometric mean for the samples collected at 100 Church Street was 6,311 str/cm^, and the geometric mean for the samples collected at 40 Worth Street was 11,561 str/cm^.
4.0 RECOMMENDATIONS AND CONCLUSION
Results of equipment sampled at both locations exceed the clearance criterion for this project which was set at the geometric mean target concentration of less than 1,000 str/cm^ for the sample set. Individual samples were also found to exceed the 10,000 str/cm’ individual sample target concentration. The elevated levels indicate that dust within the equipment is contaminated with asbestos, TRC recommends that the equipment be disposed of or cleaned using High Efficiency Particulate Air (HEPA) vacuuming and wet wiping methods, as appropriate. TRC recommends cleaning of equipment be performed by a licensed asbestos abatement contractor under controlled conditions to prevent potential employee exposure to dust during cleaning. TRC can provide a short-list of licensed abatement and disposal contractors, if requested.
TRC reccommends the cleaning or disposal proceed as quickly as possible. In the interim, TRC recommends that maintenance and dissassembly of impacted equipment be limited to asbestos trained individuals. Additionally, if equipment cannot be taken out of service prior to cleaning/disposal, TRC recommends representative breathing zone asbestos air sampling and analysis via Transmission Electron Microscopy (TEM) be conducted to determine airborne concentrations resulting from use of equipment.
3
CITY_21MC100_000914573 NYC-WTC_000354042
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000318672
Asbestos micro-vacuum sampling report for Office Equipment area, 40 Worth Street/4th Floor, Jan 7, 2003.
11 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000354044
Asbestos micro-vacuum sampling report for NYC Mayor's Office of Operations; prepared by TRC Engineers.
11 shared non-person entities · 1 shared topics · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000437401
Vacuum sampling protocol and results for WTC vicinity; includes custody forms.
10 shared non-person entities · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362382
TRC asbestos micro-vacuum sampling of office equipment post-WTC; locations at 100 Church and 40 [name].
9 shared non-person entities · 1 shared topics · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436063
Vacuum sampling results and procedures for 100 Church Street site investigation, January 2003.
10 shared non-person entities · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154731
Cover page for a fax transmission from the DEP containing chain of custody records related to environmental samples or inspections.
11 shared non-person entities · similarity 0.957
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000236042
A cleaning verification report for the twentieth floor of 100 Church Street prepared by TRC Engineers for the New York City Law Department.
8 shared non-person entities · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362380
Asbestos micro-vacuum sampling report for office equipment related to WTC offices.
5 shared non-person entities · 1 shared topics · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
5 shared non-person entities · 1 shared topics · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000108678
Document page summarizing positive and negative counts for asbestos analysis via PLM, PCM, and TEM methods.
3 shared non-person entities · 1 shared topics · similarity 0.950
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000420276
Asbestos microvac data and chain-of-custody form for TRC sampling at NYC sites.
11 shared non-person entities · 1 shared topics · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000417428
Internal memorandum documenting project details and communications between parties.
4 shared non-person entities · 1 shared topics · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000318672
Asbestos micro-vacuum sampling report for Office Equipment area, 40 Worth Street/4th Floor, Jan 7, 2003.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436063
Vacuum sampling results and procedures for 100 Church Street site investigation, January 2003.
Similarity score 0.983 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000354044
Asbestos micro-vacuum sampling report for NYC Mayor's Office of Operations; prepared by TRC Engineers.
Similarity score 0.982 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000154731
Cover page for a fax transmission from the DEP containing chain of custody records related to environmental samples or inspections.
Similarity score 0.982 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000444229
Sampling results for equipment at 40 Church Street; concentrations for PCs, printers, monitors, etc., with recommendations.
Similarity score 0.982 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362382
TRC asbestos micro-vacuum sampling of office equipment post-WTC; locations at 100 Church and 40 [name].
Similarity score 0.982 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Asbestos micro-vacuum sampling report for Office Equipment area, 40 Worth Street/4th Floor, Jan 7, 2003.
Similar indexed content
NYC-WTC_000354044
Asbestos micro-vacuum sampling report for NYC Mayor's Office of Operations; prepared by TRC Engineers.
Similar indexed content
NYC-WTC_000437401
Vacuum sampling protocol and results for WTC vicinity; includes custody forms.
Similar indexed content
NYC-WTC_000362382
TRC asbestos micro-vacuum sampling of office equipment post-WTC; locations at 100 Church and 40 [name].
Similar indexed content
NYC-WTC_000436063
Vacuum sampling results and procedures for 100 Church Street site investigation, January 2003.
Similar indexed content