NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 5 pages

Analytical results, ATC Associates

Machine-extracted title · confidence 24%

Solid matrix sample results from ATC-related analysis.

NYC-WTC_000353624–000353628
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Services, Inc. 1700 Elm Street - Suite 200 Minneapolis. MN 55414

/\-^ceAn^ic^ Tel: 612-607-1700 Fax: 612- 607-6444

/ Method 8290 Analysis Results Client - ATC ASSOCIATES Client's Sample ID ATC-0911-M520-DX-3 Lab Sample ID 103850624 Filename F21017A_13 Injected By MRO Total Amount Extracted 1.00 m2 Matrix WIPE % Moisture NA Dilution NA Dry Weight Extracted NA Collected 09/11/2002 ICAL Date 10/01/2002 Received 09/12/2002 CCal Filename(s) F21016B_13 & F21017A_15 Extracted 10/10/2002 Method Blank ID BLANK-2278 Analyzed 10/17/2002 18:15 Native Cone EMPC LRL Internal ng's Percent Isomers n(|/m2 ng/m2 ng/m2 Standards Added Recovery

2,3,7,8-TCDF ND 0.00200 2,3,7,8-TCDF-13C 2.00 84 Total TCDF 0.0032 0.00200 J 2,3,7,8-TCDD-13C 2.00 84 1,2,3,7.8-PeCDF-13C 2.00 76 2,3,7,8-TCDD ND 0.00200 2,3,4,7,8-PeCDF-13C 2.00 70 Total TCDD 0.0150 0.00200 1,2,3,7,8-PeCDD-13C 2.00 73 1,2,3,4,7,8-HxCDF-13C 2.00 99 1,2.3,7,8-PeCDF ND 0.01000 1,2,3,6,7,8-HxCDF-13C 2.00 106 2,3.4,7,8-PeCDF ND 0.01000 2,3,4,6,7,8-HxCDF-13C 2.00 98 Total PeCDF ND 0.01000 1,2,3,7,8,9-HxCDF-13C 2.00 86 1,2,3,4,7,8-HxCDD-13C 2.00 101 1,2,3,7,8-PeCDD ND 0.01000 1,2,3,6,7,8-HxCDD-13C 2.00 99 Total PeCDD ND 0.01000 1,2,3,4,6,7,8-HpCDF-13C 2.00 75 1,2,3,4,7,8,9-HpCDF-13C 2.00 70 * 1,2,3,4,7,8-HxCDF ND 0.01000 1,2,3,4,6,7,8-HpCDD-13C 2.00 86 " 1,2,3,6.7,8-HxCDF ND 0.01000 OCDD-13C 4.00 74 2,3,4,6,7,8-HxCDF ND 0.01000 1,2,3,7,8,9-HxCDF ND 0.01000 1,2,3,4-TCDD-13C 2.00 NA Total HxCDF ND 0.01000 1,2,3,7,8,9-HxCDD-13C 2.00 NA

1,2,3,4,7,8-HxCDD ND 0.01000 2,3,7,8-TCDD-37CI4 0.20 87 1,2,3,6,7,8-HxCDD ND 0.01000 1,2,3,7,8,9-HxCDD ND 0.01000 Total HxCDD ND 0.01000

1,2,3,4,6,7,8-HpCDF ND 0.01000 Total 2,3,7,8-TCDD 1,2,3,4.7,8,9-HpCDF ND 0.01000 Equivalence: 0.000044 ng/m2 Total HpCDF ND 0.01000 (Using ITE Factors)

1,2,3,4,6,7,8-HpCDD ND 0.01000 Total HpCDD ND 0.01000

OCDF ND 0.02000 OCDD 0.0440 0.02000 J

LRL = Lower Reporting Limit Cone = Concentration (Totals incluile 2.3,7,8-substitute(l isomers) I = Interference EMPC = Estimated Maximum Possible Concentration E = PCDE Interference A = Detection Limit based on signa -to-noise measurement S = Saturated signal J = Concentration detected is belovr the calibration range ND = Not Detected B = Less than 10 times higher than method blank level NA = Not Applicable P = Recovery outside of target rant e NC = Not Calculated Nn = Value obtained from addition: I analysis * = See Discussion Report No.... 1062570

RE PORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

CITY_21MC100_003021614

NYC-WTC_000353627

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000353627Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →