NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Chemical analysis report, ATC samples

Machine-extracted title · confidence 44%

PCDD/PCDF analysis report for ATC-submitted samples.

NYC-WTC_000353620–000353622
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pace Analytical Services, Inc. 1700 Elm Street, Suite 2C0 ^ace Analytical’ Minneapolis, Ml\l 55414 Phone: 612.607.1700 www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fax: 612.607.6444

' PROJECT: PCDD/PCDF ANALYSES DATE: November 6, 2002

PAGE: 2 REPORT NO: 02-1062570

DISCUSSION (Cont.)

The response factors for three labeled internal standards in the end of shift calibration standard were outside the target range for this method. The response factors for these isomers from the beginning and end calibratiors were averaged to provide accurate value for these isomers, as described in the method. The affected points are flagged on the data summary sheets.

A laboratory spike sample was also prepared with the sample batch by extracting a clean wipe that had been fortified with native standard materials. The results, found at the end of Appendi,'< B, show that the spiked native compounds were recovered at 73-87%. This indicates a high degree of accuracy for these determinations.

REMARKS

The sample extracts will be retained for a period of 30 days from the date of this report and then discarded unless other arrangements are made. The raw mass spectral data will be archived on magnetic tape for a period of not less than one year. Questions regarding the data contained in this report may be directed to the authors at the numbers provided below.

Pace Analytical Services, Inc. 1

Scott;C. Unze Project Manager, Dioxins (612) 607-6383' /

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

CITY_21MC100_003021606

NYC-WTC_000353621

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000353621Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000309709

PCDD/PCDE determinations; 14-page Pace Analytical report for DOE project.

Similar indexed content

Compare copies and versions →