NYC 9/11 Public Portal Document
Attn: Mr. Bernard Orlan Received: 9/10/02 8:00:00 AM
N.Y.C. Board of Educatit ti ATC Group#: 8828
28-11 Queens Plaza North Analysis Date: 9/10/02
Long Island City, N” 11101
Fa.v: (212) 475-4122 Piione: (212) 477-8941
Project; NAT-BOE Miinay Beigrraum HS
411 Pearl Street. New York, NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
I y EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical Asbestos
Area Non Asbestos # Structures Sensitivity Concentration
Sample Coliiine Analyzed Asb Type(s) 0.5f,-5 St, (S/ccj (S/mm^) (S/cc) Notes
1928.00 0,0450 0 None Detected 0 0 0.0044 <22.24 <0.0044
S828 -17
18 1928.00 0-0450 0 None Detected 0 0 0.0044 <22.24 <0.0044
882S -18
19 I 920.00 0.0450 0 None Delected 0 0 0.0045 < 22.24 0.0045
8828 -10
20 . 1920,00 0,0450 0 None Detected 0 0 0.0045 <0.0045
8828 -20
2-i 1928,00 0,0450 0 None Detected 0 0 0,0044 <0.0044
8828 -21
1912 00 0.0450 0 None Detected 0 0 0.0045 22.24 <0.0045
882S -22
2.5 1912.00 00450 0 None Detected 0 0 0.0045 <22.24 <0.0045
8828 -23
MICHAEL .4. GORYCKI, Ph.D
MARK PEYSAKHOV
.Analyzed by: nved bv:
Disciaimer: The laboratory is not responsible lor data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel. This lab is only responsible
for data reported in structures,'mm7 This report nay not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim
product endorsement by NVLAP or any other ac ancy of the U.S. Government. This reports relates only to the samples reported above. Quality control data (including 95%
confidence limits and laboratory and analysis' accuracy and precision) is available upon request.
Accredited for NVLAP PLM/TEM #101187-0, NY State ELAP #10879
Page 3 iij ’
CITY_21MC100_003021202
NYC-WTC_000353392
OCR can misread numbers and units. Confirm readings against the page image before using them.